background image

USER MANUAL

Inteli-Mixer RM-2

12

Warranty statements

•  Warranty applies to 24 month period from the 

date of purchasing.

•  Malfunctions arisen through the fault of pro-

ducer in the course of this period, are removed 
free of charge.

•  Guaranty is not valid in the following cases:

 -

If the serial number label of the manufac-
turer is damaged.

 -

If damages appears as a result of the incor-
rect operation, transportation or storage.

•  These documents are necessary if applying for 

warranty repair:

 -

User manual with serial number of the ma-
chine.

 -

Officially signed report, describing the rea-
sons and conditions of equipment mal-
function.

•  Warranty repair could be performed only if the 

equipment is delivered in the original manu-
facturers packaging or equally safe packaging. 
Therefore please keep the transportation pack-
aging after unpacking the device.

•  If the above warranty requirements are dis-

turbed, repair charges are applied to the con-
sumer.

For all further questions concerning exploitation 
and maintenance please
Contact manufacturer or product vendor.

Certificate of approval

Inteli-Mixer RM-2 ____ 

N

__________________________________________

has been inspected for the technical conditions 

and meets all regulations necessary for this class 

of device.

Quality control person _____________________________ 

 (name) (signature)

Date of manufacture  ______________________________

Place for stamp.

Certificate of sale Organization _____________________

Address 1 line  _____________________________________

Address 2 line  _____________________________________

Phone  _____________________________________________

Vendor   ________________________ (name) (signature).

Date of sale  ________________________________________

Phone:

 

(805) 375-0060

 3483 Old Conejo Rd., STE 206

Newbury Park, CA 91320

[email protected]

elminorthamerica.com

North America

Phone:

 

(371) 6755-8743

21-133 Aizkraukles Str., Riga LV-1006 

Fax: (+371) 6755 1934

E-mail: [email protected]

www.elmi-tech.com

Europe

© ELMI North America, Inc. 2021

Содержание Inteli-Mixer RM-2

Страница 1: ...USER MANUAL RM 2L RM 2M RM 2S elminorthamerica com Inteli Mixer RM 2...

Страница 2: ...ms F4 F5 F6 F8 F9 6 Customer programs C1 C2 C3 6 Creating customer programs 6 Introduction 6 Entering programming mode 7 Programming mode 7 Learning to use program steps 8 Spinning 8 Temporary pause 8...

Страница 3: ...speed rev min from 1 to 99 Speed selection step rev min 1 Environmental temperature C from 2 to 50 Relative moisture of the atmosphere at the temp 20 C not more than 80 Power adapter input 110 220 V...

Страница 4: ...on On is on the top of the control block Power supply socket is on the back side of the control block Rack to motor connector is on the right side of the control block Back holder Base platform START...

Страница 5: ...ckwise rotation 1 5 sec Hold in initial point F8 110 clockwise rotation 1 5 sec big amplitude U shaking 110 counter clockwise rotation 1 5 sec Hold in initial point 110 counter clockwise rotation 1 5...

Страница 6: ...cy until operation become stable Combined programs F4 F5 F6 F8 F9 These programs are performing different combina tions of rotation and vortexing Current speed is shown on RPM display and can be chang...

Страница 7: ...s and displays acquire additional functions See figure 2 During programming mode RPM display shows rack rotation angle relatively to initial position See dia gram on fig 4 Program seletion buttons Ste...

Страница 8: ...hile entering long programs it is recommended to enter positioning correction each time we pass 00 vertical position point This can be done by selecting SP function in 00 point F display shows P0 and...

Страница 9: ...tor that corresponds to 270 degrees see Fig 3 2 9 Press enter button 2 10 Pressing clockwise rotation button or coun ter clockwise rotation button set 00 value on RPM indicator F indicator will show...

Страница 10: ...g buttons select operation program see Intelli mixer program overview table Set rotation speed and shaking intensity see using mixing programs Note Operation programs can be selected either during ope...

Страница 11: ...emory is empty Enter a new custom program See creating custom programs Disinfection and cleaning Before you start disinfection or cleaning make sure the power adapter is unplugged It is recommended to...

Страница 12: ...harges are applied to the con sumer For all further questions concerning exploitation and maintenance please Contact manufacturer or product vendor Certificate of approval Inteli Mixer RM 2 ____ N0 __...

Отзывы: