USER MANUAL
Inteli-Mixer RM-2
8
Learning to use program steps
The full circle of rack rotation is split in to 100 steps
from 1 to 99. For example 25 steps are equal to 90
degree turn.
Spinning:
Pressing clockwise rotation button or counter
clockwise rotation button will set the desired
rotation angle value (see Fig. 4).
F display will show
SP. Press enter button to save rotation value in
the memory. When rack reaches starting initial 00
point,
F display shows P0.
If you wish to finish creating program press in
P0
point and it will exit and save program in memory.
Temporary pause
Select
PP function on F display. Press button and
enter pause function in the memory. You have set
1.5 sec. Pause. Each time you press button it will
increase pause time by 1.5 sec.
Note !
each push of button counts as one step of a
program.
Big amplitude shaking ‘U’
Select PU function on F display. Press button to
input this function in the memory. You have entered
1.5 sec. big amplitude shaking. Each time we press
button it will increase shaking time by 1.5 sec.
Note !
each push of button counts as one step of a
program.
Small Amplitude shaking ‘u’
Select
Pu function on F display. Press button to
enter this function in the memory. You have en-
tered 1.5 sec. Small amplitude shaking. Each time
we press button it will increase shaking time by
1.5 sec.
Note !
each push of button counts as one step of a
program.
Entering position correction
While entering long programs it is recommended to
enter
positioning correction each time we pass 00
vertical position point.
This can be done by selecting
SP, function in 00
point (
F display shows P0) and pressing button.
If we would like to enter any other function like
PP,
PU or Pu in 00 position, scroll the F display menu for
desired function and press button.
PP, PU & Pu
function entered in
00 position also make position
correction.
Ending the custom program
By scrolling clockwise & counter clockwise
find the initial vertical rack position,
F display will
show
P0 and RPM display will show 00.
Press
button to enter
P0 end of program func-
tion.
Now press button to launch created program
and check if program works correctly.
Tip !
It is possible to end a program and exit program-
ming mode any time by holding button for 4,5 sec-
onds, however it may cause incorrect operation as it is
necessary to enter programs’ end point P0.
Erasing custom program
Select custom program, which you want to erase on
F display.
Enter the programming mode (See
Entering pro-
gramming mode).
Press
button while F display shows
P0, this will
erase previously entered program and set simple
rotation program as a default.
Tip !
If maximal number of 78 steps of the program is
exceeded, program will break and exit programming
mode. For correct performance it is necessary to re-
duce number of steps and input program again.
Tip !
Custom programs C1, C2 & C3 could be repro-
grammed over 100’000 (!) times. Since custom program
is entered it will remain in the memory until operator
decides to reprogram or erase it and will not erase af-
ter power cut off.