6. Choose if limit value 2 is a min
( -LO- )
or max-function
( -HI- )
,
use
+
. Confirm with
=
.
7. The diode at
X1
is activated. On display:
100.0
. If another limit value is desired, use
+
and
-
to set a new value. Confirm with
=
. On display:
-HI-
.
8. Choose if limit value 3 is a min
( -LO- )
or max-function
( -HI- )
,
use
+
. Confirm with
=
.
9. The diode at
X2
is activated. On display:
100.0
. If another limit value is desired, use
+
and
-
to set a new value. Confirm with
=
. On display:
-HI-
.
10. Choose if limit value 4 is a min
( -LO- )
or max-function
( -HI- )
,
use
+
. Confirm with
=
.
5.2.2b) On/Off regulation
1. The diodes at
PWM, FRK, P-BAND
and
I-TIME
is activated, the display shows
OnOF
.
Choose between On/Off regulation and proportional regulation, use
+
.
Press
=
to confirm.
2. The diode at
ALARM
is activated, the display shows
0300
. Set the time delay, in seconds,
using
+
and
-
.
Press
=
to confirm.
3. Decide the function shutdown at alarm shall be on (
Shon
) or off (
ShoF
) with
+
. Press
=
to
confirm.
3.
Step to
EXIT TO MEASURE
by pressing
M
repeatedly. Press
=
to start measuring.
5.2.2c) Proportional regulation
1. The diodes at
PWM, FRK, P-BAND
and
I-TIME
is activated, the display shows
OnOF
.
Choose between On/Off regulation and proportional regulation, use
+
.
Press
=
to confirm.
2. The diode at
FRK
is activated, the display shows
On
. If frequency related regulation is
desired, press
=
to confirm. If pulse width modulated regulation is desired, press
+
until
the display shows
Off
, then press
=
to confirm. The diode at
PWM
is activated, the
display shows
On
.
Press
=
to confirm.
Frequency related regulation
If pulse width modulated regulation is desired, see below
3. The diode at
FRK
is activated, the display shows
0180
. Set the max frequency
(pulses/minute), use
+
and
–
. Press
=
to confirm.
4. The diode at
P-BAND
is activated, the display shows
0100
.
Set the proportional band in %
of total range. Use
+
and
-
. Press
=
to confirm.
5. The diode at
I-TIME
is activated, the display shows
0050
.
Set the integration time (if no
integration is desired, set
0000
).
Use
+
and
-
. Press
=
to confirm.