background image

Elma Schmidbauer GmbH

7 Unit description

Elmasonic Select

15 / 32

Unit description

1

2

3

5

6

7

8

9

10

4

Illustration 2: 

Operating side/rear side

1 Warning of hot surfaces

7 Rotary switch, open/close drain

2 Display, splash-proof

8 Feet, non-slip

3 Handle

9 Membrane keyboard, wipeable

4 Mains connection

10 Blower on the unit base (not shown) (not

available for Elmasonic Select 30–100)

5 Nameplate, not shown

11 Ball valve, open/close drain (Elmasonic Select

500/900)

6 Drain (not available for Elmasonic

Select 30/40/500/900)

11

Illustration 3: 

Drain of Elmasonic Select 500/900

Содержание Elmasonic Select

Страница 1: ...04 2021 Translation of the original manual Elmasonic Select Ultrasonic cleaning unit english Version 1 Item No 1112616...

Страница 2: ...ts reserved Elma Schmidbauer GmbH Gottlieb Daimler Strasse 17 78224 Singen Germany www elma ultrasonic com Technical Support Tel 49 7731 882 280 Email support elma ultrasonic com Subject to technical...

Страница 3: ...unit 18 9 1 Notes on installation site 18 9 2 Set up the unit 19 9 3 Connect the unit 19 10 Insert objects to be cleaned 20 11 Fill the tank 20 12 Operating the unit 21 12 1 Switch on the unit 21 12 2...

Страница 4: ...They must have read and understood the manual and be capable of following all notes and instructions All tasks that go beyond the pure operation of the unit within the scope described here must be per...

Страница 5: ...Unauthorised persons in particular children must not use this product Only use original accessories made for this product 2 2 Misuse Misuse refers to any use of the unit that deviates from proper use...

Страница 6: ...Death or serious injury WARNING Possible dangerous situation Death or serious injury CAUTION Possible dangerous situation Slight injuries damage to components or units NOTICE Useful advice or tip No...

Страница 7: ...proved for this unit In case of doubt ask the manufacturer or supplier Infections Danger of possible infection due to poor cleaning results dirty cleaning fluid and insufficient maintenance and disinf...

Страница 8: ...women must not be subjected to the noise emissions for longer periods of time Keep animals away from the vicinity of ultrasonic devices Electromagnetic radiation No binding statement can be made for p...

Страница 9: ...ration of liquids and form extremely fine mists that readily ignite on contact with sources of ignition This can result in severe burns or death Do not use cleaning agents that are labelled with the p...

Страница 10: ...L 1 6 2 9 4 3 Weight unit with cover kg 3 6 3 8 5 2 Performance data Total power consumption W 320 320 550 Effective ultrasonic power 10 W 120 120 150 Peak ultrasonic output max W 480 480 600 Heating...

Страница 11: ...s W D H unit with cover mm 575 360 230 405 360 330 575 360 330 Interior dimensions W D tank below fill level marking mm 485 280 300 370 475 270 Fill level tank base to fill level marking mm 65 165 165...

Страница 12: ...marking mm 500 330 600 500 Fill level tank base to fill level marking mm 235 200 Working height basket base to fill level marking mm 220 190 Recommended tank operating capacity L 40 3 63 7 Weight uni...

Страница 13: ...rget temperature C 80 Degree of protection IP20 Protection class I Ambient conditions Temperature transport C 15 to 60 Temperature operation storage C 5 to 40 Air pressure transport storage hPa 500 1...

Страница 14: ...a damaged unit into operation Dispose of packaging materials that are no longer required in an environmentally friendly manner 1 2 3 4 5 6 Illustration 1 Included items schematic diagram 1 Ultrasonic...

Страница 15: ...tch open close drain 2 Display splash proof 8 Feet non slip 3 Handle 9 Membrane keyboard wipeable 4 Mains connection 10 Blower on the unit base not shown not available for Elmasonic Select 30 100 5 Na...

Страница 16: ...art long press 4 Temperature display value unit symbol 5 Plus minus buttons set temperature programme memory parameter values short press quick cycle long press 6 Select button to switch between progr...

Страница 17: ...pulse to improve the overall cleaning power 8 2 Operating status symbols The following symbols are shown on the display as soon as the unit enters the respective operating status End of cleaning Ultr...

Страница 18: ...arameters Set operating parameters During Normal mode Current operating status Programme mode The unit is ready to use Four stored programmes can be selected for ultrasonic cleaning The programmes can...

Страница 19: ...ts etc on hand Place the unit on the selected surface IMPORTANT The controls such as the display buttons and if applicable discharge tap must be clearly visible and easily accessible The unit has been...

Страница 20: ...nded for use in ultrasonic cleaning are water softened water or distilled water Cleaning power can be improved by adding suitable cleaning agents The unit and the tank are clean and if necessary disin...

Страница 21: ...ion Pregnant women must not spend long periods of time near an ultrasonic unit in operation Keep animals away from the ultrasonic unit CAUTION Dry running Damage to the tank and unit Always fill the t...

Страница 22: ...own to increase decrease the duration more quickly 12 3 Set the target temperature From 25 80 C 77 176 F Press one of the Plus minus buttons below the temperature display to set the required target te...

Страница 23: ...controlled start Use this function to start ultrasound operation automatically once the target temperature has been reached IMPORTANT When cleaning sensitive objects please note that the ultrasound i...

Страница 24: ...e the current temperature and the set ultrasound mode are continuously shown on the display The ultrasound mode temperature duration and heating On off can be changed during ultrasonic cleaning IMPORT...

Страница 25: ...uttons to select a programme Press the Start stop button to start the displayed programme The Remaining time and Heating symbols will be shown on the display if saved The remaining time the current te...

Страница 26: ...her ultrasonic cleaning process Switch off the unit If the fluid is dirty or will not be used again empty out the liquid See the section Drain the unit for information 13 Drain the unit CAUTION Hot li...

Страница 27: ...chapter Maintenance for information CAUTION Never submerge the unit in water The unit is emptied cleaned and where necessary disinfected 14 Change parameters in Setup IMPORTA NT If parameters marked...

Страница 28: ...ff melody 1 melody 2 06 Acoustic signal for Error message 00 01 02 Off melody 1 melody 2 07 Acoustic signal for Temperature limit exceeded 00 01 02 Off melody 1 melody 2 08 Response if temperature lim...

Страница 29: ...ltrasonic operation does not start Ultrasonic unit defective Contact the manufacturer Display shows Er Error message Check the error code and rectify the fault contact the manufacturer if necessary Bl...

Страница 30: ...after approx one minute The unit has been reset to factory settings The error number displayed is not listed here make a note of the error number the unit must be repaired at the factory IMPORTA NT Em...

Страница 31: ...the tank 8 Use a damp cloth to wipe out the remaining limescale and dirt residue If necessary rinse the tank using a shower set CAUTION Do not spray the outside of the unit with water The tank has be...

Страница 32: ...if any LED indicators are not displayed The unit has been switched off Hold down the Mode button until the Setup menu is shown on the display To set the LED test function press the Plus minus buttons...

Отзывы: