![Ellard V3D Maxi Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/ellard/v3d-maxi/v3d-maxi_product-instructions_2393650003.webp)
Power Supply
/- 10% or /- 10%
Working Temp
Max Accessories Load
Max Motor Load
Humidity
Up to 93% RH Non Condensing
0.75kW @ 230VAC or 2.2kW @ 400VAC
1
00mA @ 24v d.c
The LCCV3D (Maxi) Controller is designed with limited capabilities to operate an industrial door safely under
electrical control by means of a push button or key-switch control
Its intended use is to be connected to a suitable motor not exceeding the maximum load for the controller
Connections are provided for Mains supply, Motor power, Mechanical or Electronic travel limits, External Push
Buttons, Pneumatic, Electrical or Optical Safety Edge, Photocell, 24vDC aux power (100mA). Optional Plug in
Connections for Radio Control and Traffic Light function
basic functions include - STOP, OPEN, CLOSE, and Auto-close via time delay provided suitable monitored safety
devices are connected
Features
Compact unit, suitable for Low or High Level mounting in a separate enclosure
Suitable for Mechanical or Electronic Limits
Auto Detection of Encoder type fitted (Dalmatic, KOSTAL, Feig)
Auto detection of all Connected Safety Devices eg. Photocell, Safety Edge (8K2, Optical,
Pneumatic Air Switch) to Performance Level 'C' with quick Set Up
Full LED Diagnostics
Auto close delay time 1 - 240 sec's
Run Timer 120 sec's
Facility for additional Traffic Light Card (00106)
Radio control operation via 'Teleco' plug in receiver (00107) 1ch Transmitter (00130)
Force control - for motors with sensor fitted
Selectable safety edge reverse time with super fast mode
Operation by either on membrane buttons or External push button / key-switch connection
Go function
Low Voltage control circuit
Max load: - 2.2kW @ 400v (or) 0.75kW @ 230v
Auxiliary 24v DC supply, Max load 100mA
Service Counter
Power Supply Requirements
230v AC 50Hz (1ph) or 400v AC 50Hz (3ph) (selectable) Mains power supply
Neutral connection not required to power the control board
Recommended power supply protection by:
6A Type 'C' Single Pole MCB - 1ph (or)
10A Type 'C' Triple Pole MCB - 3ph
1) Features and Specification
EN61000-6-3 (2007)
Directives - EMC
Directive 2014/30 EU
Emission
Residential
EN61000-6-1 (2007)
Immunity
Residential
Industrial
Industrial
Emission
Immunity
EN61000-6-4 (2007)
EN61000-6-3 (2005)
EN61000-4-3 (2006) +A1(2008) +A2 (2010) RF-field immunity
EN60335 -1 (2012) Safety of Household and similar electrical appliance/ Part 1
Directive - Low Voltage
Directive
LVD 2014 /35 EUC
Must be fitted to an enclosure with a minimum rating of IP54
3