![Ellard V3D Maxi Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/ellard/v3d-maxi/v3d-maxi_product-instructions_2393650012.webp)
(2.2.5) Quick Set Up - Electronic Limits
Any Safety
Devices
used?
Yes
Connect
safety devices
where shown
No
Fit Motor and
Mains Power
Connections
Fit Links and Encoder
Wiring as shown in either
2.4.2 (Dalmatic Encoder)
or
2.4.3 (KOSTAL Encoder)
Press and hold
OPEN
and
STOP
buttons together until
'CONF'
LED comes on
(approx 10 sec's) - Then release
'FAULT'
LED will begin
to flash twice
Briefly press
open button
Does door
travel up?
Yes
No
Turn
DIP Sw10 = ON
Run door to
CLOSE
position
and set
Press
STOP
button
once
Correct motor
direction
Any Safety
Devices
used?
Yes
No
Set
Dip Sw 1 = ON
(Impulse OPEN)
Dip 2 = ON
(Impulse CLOSE
)
Set
Dip Sw 1 = ON
(Impulse OPEN)
Dip 2 = OFF
(dead-man CLOSE)
Run door to
OPEN
position
and set
Press
STOP
button
once
12
Содержание V3D Maxi
Страница 20: ......