![Ellard V3D Maxi Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/ellard/v3d-maxi/v3d-maxi_product-instructions_2393650018.webp)
100's
1,000's
10,000's
100,000's
10's
8
2
3
0
0
Press OPEN
Press OPEN
Press OPEN
Press OPEN
80
200
1,000
0
0
1
2
1
4
5
No of Yellow
No of Red
1200
Count =
(2.8) Service Counter
The V3D incorporates an in built counter that registers how many operations the
door has performed
This counter is not pre-settable, it is a counter only and can only be read using the
LED indicators at a periodic service interval that is agreed by the installer
To read the service counter proceed as follows:
Send door to full close position then press OPEN and CLOSE simultaneously then release
Observe the number of flashes of the (yellow) STOP and (red) FAIL LED's
OPEN button moves to the next column
CLOSE button moves to the pervious column
STOP button returns to normal run
First column to be
read is the
10's
1 x yellow STOP
LED
followed by (x) no
of red FAIL LED
Press OPEN
button once
Next column to be
read is the
100's
2 x yellow STOP
LED
followed by (x) no
of red FAIL LED
Next column to be
read is the
1,000's
3 x yellow STOP
LED
followed by (x) no
of red FAIL LED
Next column to be
read is the
10,000's
4 x yellow STOP
LED
followed by (x) no
of red FAIL LED
Last column to be
read is the
100,000's
5 x yellow STOP
LED
followed by (x) no
of red FAIL LED
Press OPEN
button once
Press OPEN
button once
Press OPEN
button once
Example:
Note:
Units are not
displayed
18
To Reset Service counter:
1.
Close door fully
2.
Press both OPEN and CLOSE
simultaneously then release
3.
Do not exit this mode for 4 minutes
Содержание V3D Maxi