![Ellard V3D Maxi Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/ellard/v3d-maxi/v3d-maxi_product-instructions_2393650011.webp)
(2.2.4) Quick Set Up - Mechanical Limits
Any Safety
Devices
used?
Yes
Connect
safety devices
where shown
No
Fit Motor and
Mains Power
Connections
Fit Links as shown
in 2.3.2
Press and hold
OPEN
and
STOP
buttons together until
'CONF'
LED comes on
(approx 10 sec's) - Then release
'FAULT'
LED will begin
to flash twice
Briefly press
open button
Does door
travel up?
Yes
No
Turn
DIP Sw10 = OFF
Run door to
CLOSE
position
and set
Close Limit Cam
Run door to
OPEN
position
and set
Open Limit Cam
Correct motor
direction
Any Safety
Devices
used?
Yes
No
Set
Dip Sw 1 = ON
(Impulse OPEN)
Dip 2 = ON
(Impulse CLOSE)
Set
Dip Sw 1 = ON
(Impulse OPEN)
Dip 2 = OFF
(dead-man CLOSE)
Press
STOP
button
once
'FAULT'
LED will
stop flashing
11