61/68
MWA60R/T
16.0 DISQUALIFICATION TECHNICAL FEATURES
Rated voltage ............................................................................. 12 V
─
Operating voltage ....................................................................... 11.5 V
─ ÷ 15 V─
Absorption at rest, at 12 V
─ ....................................................... TX= 31 mA ; RX= 70 mA
Absorption in alarm conditions, at 12 V
─ .................................... TX= 31 mA ; RX= 70 mA
Microwave work frequency ......................................................... 10.525 GHz (± 20MHz)
Radiated power .......................................................................... 25 dBm (316 mW) peak
Modulation channels .................................................................. 5 (able to be selected)
Max. range ................................................................................. 60 m
Alarm output (Relay) N.C. - max. 500 mA at 12 V
─
Anti-tamper output (Microswitch)
– max. 50 mA at 12 V─
Disqualification output (Transistorized output)
– max. 50 mA
Test point output ........................................................................ For checking the received signal
Operating temperature ...............................................................
–20°C ÷ +55°C
It is recommended that the optional
heating kit (RS/MWA model) should
be integrated in case of outdoor
installation.
Degree of protection .................................................................. IP 34
Dimensions: (h. x l. x d.) ............................................................. 230 x 176 x 133 ± 2 mm.
Содержание MWA60R/T