13/28
EL50RT 2PH 150m
- WIRING
DISTANCE
WIRE SIZE
12Vdc
24Vdc
0.5 mm
2
250m
2200m
1 mm
2
440m
4000m
Note:
1. When two or more connections is required,
maximum wiring distance is the value above divided
by the number of sets.
2. The power wires could not exceed the above
mentioned lengths.
- CONNECTION SAMPLE
Sample 1
Sample 2
Sample 3
4.0 INSTALLATIONS
The units can be mounted easily on a pole or flat surface.
- Remove cover via screw at base of cover.
- And loosen the unit base mounting screw and remove mounting plate by sliding it against the unit base.
A. Wall mounting
- Pull out the wire through the wiring hole on the mounting plate
and attach the plate to the wall with the screw ( 1/6ªx 3/4ª)
- Connect wire to the terminals.
- After checking optical alignment and operation check, ( please see 7.ALIGNMENT AND OPERATION )
replace the cover, and fasten the cover lock screw tightly.
B. Pole mounting
Power
Alarm signal
Power
Alarm (Ch2)
Alarm signal
Power
Alarm (Ch3)