12/28
EL50RT 2PH 150m
- DETECTION RANGE
Max detection range is 300m (outdoor) and 150m (indoor)
- DETECTION WIDTH
The detection width can be calculated with following formula :
Width (A) = 0,025 x Length (L)
L A
60m
1,5m
100m 2,5m
150m 3,8m
- INSTALLATION HEIGHT
To detect the intruder efficiently, the sensors should
be installed within 32"~40" (80~100cm) height.
- ALIGNMENT ANGLE
The sensors can be adjusted with Horizontal
±
90°
and Vertical
±
10° to fit big detection range.
3.0 WIRING
- Transmitter
- Receiver
Transmitter
Receiver
Protection distance
Power 10.5V to 30VDC
(non-polarity)
Power
10.5V to 30VDC
(non-polarity)
Alarm output
Dry connect relay
output NC./NO.
28VDC / 0.2A
Tamper output
Dry connect Micro
SW. Output NC.
28VDC / 0.2A
Содержание EL50RT 2PH
Страница 27: ...27 28 EL50RT 2PH 150m ...