8
DS80MM1L-001
Installation
Use as opening detector:
The detector may be installed in either of the two possible vertical positions.
The distance between the device and the magnet must not be more than 15 mm when the door is closed.
Avoid installation on metal surfaces, if possible.
Install the device as high as possible.
Use as shock/vibration detector:
The device can be installed on perfectly flat concrete or wood surfaces or on window and door frames.
When installed on windows or doors, it can also be used as an opening detector.
IMPORTANT NOTE:
Detection on
multilayer or mesh glass is not guaranteed because the vibrations are attenuated by the materials.
Use the following table as a reference for the selection of materials and detection parameters.
Window glass
Door
Masonry
Thickness
> 5mm
<40mm
-
Material
Normal or tempered
Wood/steel
Cement/concrete
Positioning
Mobile window frame
Door frame
On the wall near the detection point
Detection type
Single pulse
Multiple pulse / sum of vibrations
detection
Detection
diameter for
different
sensitivities
Low
2m
1m
0.5m
Medium
3m
2m
1.5m
High
4m
3m
2m
Installation
1. Open the device by
undoing the cover fixing screw.
2. Break the hole pattern on the base.
3. Using the base as a template for the holes, make the holes in the installation surface.
4. Insert the anchor bolts.
5. Screw the base to the anchor bolts using the flat head screws provided.
6. Fix the cover to the base and tighten the cover fixing screw.
7. Fix the magnet with screws or double-sided adhesive tape.
<
<
N
N
O
O
T
T
E
E
>
>
Do not install the device on a surface subject to frequent vibrations to prevent false alarms.
Coverage area:
up to 2 m
Coverage area:
up to 1,5 m
Coverage
area: up to
2 m on
each
window
Door
Window
Window