USING THE EXTENSION TERMINAL.

 

  If the Door Contact cannot be mounted on the door frame, you 

can  connect  an  additional  “

extension  magnet  switch

”  to  the 

Extension Terminal

” and mount the Door Contact remotely. 

  More  than  one  window  and  door  can  be  protected  by  a  Door 

Contact  using  an  additional  magnet  and  extension  magnet 
switch.    The  switches  must  be  wired  to  the  auxiliary  terminal 
block as shown Fig.1. 

  Any  device  with  N.C.  (Normally  Closed)  dry  contact,  such  as 

broken  glass  detector,  Smoke  Sensor,  gas  detector,  water 
leabag  detector  etc,  can  be  connected  to  the  “

Extension 

Terminal

” Making the Door Contact served as an “

Universal Transmit

”. 

Note:

 

  The  Extension  Terminal  form  a  closed  loop  with  the  device 

connected to  it. When the  Loop  is  opened  (the device  is  triggered), 
the Door Contact is activated. 

  The device connected to the Extension Terminal is in series with the 

internal magnet Switch.  That means both of them will work together 
at the same time. 

 

TECHNICAL CHARACTERISTICS 

Frequency band: ........................................................................... 868.35 MHz 
Output power (Max): ......................................................................... - 3.1 dBm 
 

 

 

           IDENTIFICATION DES PIÈCES

 

Déposez le capot en desserrant la vis de fixation située au fond, pour présenter le détecteur 

d’ouverture 

comme illustré. 

 

   

Voyant lumineux                                               

  

Borne d'extension   

 

  

Commutateur anti-sabotage                             

  

Bouton apprentissage/test 

 
 
 
 

 

 

 JP1   Cavalier test/mode normal 

 

ON,   le détecteur 

d’ouverture est en mode test. 

OFF, le détecteur 

d’ouverture est en mode normal. (Option d'usine par défaut) 

 

 

JP2

   

Cavalier habilite/déshabilite signal vérification  

ON, signal vérification déshabilite (Option d'usine par défaut) 
OFF, signal vérification habilite 

 

 JP3 Cavalier de dérivation du commutateur à aimant interne

 

ON, le commutateur à aimant interne est dérivé. Seul le dispositif connecté à la borne d'extension active 
le détecteur. 
OFF, le commutateur à aimant interne est utilisé. (Option d'usine par défaut) 

 

 JP4 Cavalier habilite/déshabilite la confirmation état " fermé " 

 

ON :  le détecteur ne transmet pas  l'état " fermé"  
OFF: le détecteur il transmet l'état " fermé" (Option d'usine par défaut) 

VOYANT LUMINEUX

 

En mode de fonctionnement normal, le voyant lumineux ne s'allume que dans les situations suivantes : 

  Lorsque le capot est ouvert et que le commutateur anti-sabotage est violé, le voyant s'allume. 

  Lorsque le sabotage perdure ou que le détecteur 

d’ouverture est en état de pile faible, le voyant 

s'allume à chaque activation du détecteur de porte. 

Toutefois, lorsque le détecteur est en mode test, le voyant clignote à chaque activation. 

Cavalier On 

Le cavalier est inséré pour 
connecter les deux broches

 

Cavalier Off 

si le cavalier est retiré ou « 

parqué 

» sur une broche.

 

Содержание DC200

Страница 1: ... Jumper ON Door Contact will not send Door Close signal to Control panel Jumper OFF Door Contact will send Door Close signal to Control panel Factory default LED INDICATOR In Normal operation mode the LED indicator remains off except in the following situations o Cover is opened and the tamper switch is violated LED will light o A Tamper Condition persists or Door Contact is in Low battery conditi...

Страница 2: ...xt remove the other cover and firmly press the item onto the desired location Note Do not use the adhesive pad method of installation on rough surface or with peeling cracked paint Screw Mounting The Base has two knockouts for mounting purpose where the plastic is thinner To mount the Door Contact 1 Remove the cover 2 Break through the knockouts on the base 3 Using the holes as a template drill ho...

Страница 3: ...ineux Borne d extension Commutateur anti sabotage Bouton apprentissage test JP1 Cavalier test mode normal ON le détecteur d ouverture est en mode test OFF le détecteur d ouverture est en mode normal Option d usine par défaut JP2 Cavalier habilite déshabilite signal vérification ON signal vérification déshabilite Option d usine par défaut OFF signal vérification habilite JP3 Cavalier de dérivation ...

Страница 4: ...ement voulu et appuyez sur le bouton de test pour confirmer que l emplacement se situe à portée de la centrale Après vous être assuré que le détecteur d ouverture fonctionne à l emplacement choisi vous pouvez procéder à l installation MÉTHODES DE MONTAGE Vous pouvez installer le détecteur d ouverture selon deux méthodes En utilisant une fixation autocollante ou vissée Installation autocollante 1 N...

Страница 5: ...le détecteur d ouverture sur le cadre de la porte vous pouvez connecter un commutateur à aimant d extension à la borne d extension et monter le détecteur d ouverture à distance Plusieurs fenêtres et portes peuvent être protégées par un détecteur d ouverture en utilisant le commutateur à aimant d extension Les commutateurs doivent être câblés à la borne auxiliaire comme illustré Tout dispositif à c...

Страница 6: ... 2 Jahren ein Durchschnittsverbrauch von 50 Tagesaktivierungen Die niedrige Batterie Warnung startet normalerweise 30 Tage bevor die Batterien komplett aufgebraucht sind Hinweis Wenn Sie die Batterien wechseln drücken Sie nachdem Sie die alten Batterien entfernt haben den Sabotagekontakt zweimal um ihn völlig zu entladen bevor Sie die neuen Batterien einlegen ÜBERWACHUNGSSIGNAL Nach der Installati...

Страница 7: ...e sicher dass die Sabotagekontaktfeder so positioniert ist dass diese durch die Öffnung der Basis einen Kontakt mit der Montageoberfläche herstellt Fenster können auf dieselbe Weise gesichert werden Für Fenster befestigen Sie den Magneten an dem beweglichen Teil des Fensters und den Türschalter am Rahmen Schritt 4 Aufsetzen des Deckels an seiner Basis und mit der Schraube befestigen Schritt 5 Test...

Страница 8: ...ess www elkron com FRANÇAIS DECLARATION UE DE CONFORMITE SIMPLIFIEE Le soussigné URMET S p A déclare que l équipement radioélectrique du type CONTACT D OVERTURE DC200 est conforme à la directive 2014 53 UE Le texte complet de la déclaration UE de conformité est disponible à l adresse internet suivante www elkron com DEUTSCH VEREINFACHTE EU KONFORMITÄTSERKLÄRUNG Hiermit erklärt URMET S p A dass der...

Отзывы: