1/8
PARTS IDENTIFICATION
Remove cover by loosening the bottom fixing screw revealing the inside of the Door Contact.
LED indicator
Learn / Test button
Tamper Switch
Extension Terminal
JP1 = Test / Normal Mode Jumper
Jumper (ON): Door Contact is in Test mode.
Jumper (OFF): Door Contact is in Normal mode (
Factory default
).
JP2 = Supervision Enable / Disable Jumper Switch
Jumper (ON): Supervision disabled (
Factory default
).
Jumper (OFF): Supervision enabled
JP3 = Internal Magnet Switch Bypass Jumper Switch
Jumper (ON): the internal magnet switch is bypassed. Only the device connected to the Extension
Terminal will activate the Door Contact.
Jumper (OFF): the internal magnet switch is in use (
Factory default
).
JP4 = Door Close Confirmation Enable / Disable Jumper Switch
Jumper (ON): Door Contact will not send Door Close signal to Control panel.
Jumper (OFF): Door Contact will send Door Close signal to Control panel (
Factory default
).
LED INDICATOR
In Normal operation mode, the LED indicator remains off except in the following situations:
o
Cover is opened and the tamper switch is violated, LED will light.
o
A Tamper Condition persists or Door Contact is in Low battery condition, every time the Door
Contact is activated, the LED will light.
However, if the Door Contact is in Test mode, the LED will light every time it is activated.
BATTERY
The DC200
uses two 1.5V “
AAA
” alkaline batteries with life expectancy of 2 years (an average of 50 day
activations).
Low battery warning typically starts 30 days before complete exhaustion.