background image

iii

FOREWORD

Note:

  This Manual, P/N 98613000, is to be used by qualified and trained personnel, knowledgeable 

of 

NFPA standards and any other applicable standards in effect.

This Manual is intended to provide guidance to qualified technical professionals for the 

installation, operation and maintenance of the HydroBlast™ Intelligent Mining washdown 

cannon system.

Only qualified persons experienced and trained in the installation of this type of equipment 

should install and configure the HydroBlast. They must be familiar and experienced with 

the wiring diagrams and components,electrical installation, and familiar not only with NEC, 

relevant NFPA and local codes but also trained and qualified by Elkhart Brass Manufacturing 

Company, Inc (a Safe Fleet Company). Elkhart Brass Manufacturing Company, Inc. is a 

manufacturer of the components that make up the HydroBlast washdown system, and may 

not have the opportunity to visit the sites where the product is installed or intended to be 

installed. It is the responsibility of the professional installer (described above) to properly 

install and configure the systems. Under no circumstances will Elkhart Brass Manufacturing 

Company, Inc. be liable for improper installation or configuration of the systems.

The technical data contained herein is provided for informational purposes only, and should 

not be used as a substitute for professional judgment. Although, Elkhart Brass Manufacturing 

Company, Inc. believes this information to be true and correct, it is published and presented 

without any guarantee or warranty whatsoever. Elkhart Brass Manufacturing Company, Inc. 

disclaims any liability for any use of the data other than as set out in this manual, foreword 

included.

Any questions concerning the information presented in this manual should be addressed to:

Elkhart Brass Manufacturing Company, Inc.
1302 West Beardsley Avenue
Elkhart, IN 46514, USA 
Phone: 1-574-295-8330
www.elkhartbrass.com

Содержание HydroBlast 7100MG EXM2

Страница 1: ...98613000 REV Rel HydroBlast 7100MG EXM2 Water Cannon Installation Operating Maintenance Instructions 1 574 295 8330 www elkhartbrass com...

Страница 2: ...LS REQUIRED 2 1 2 3 INSTALLATION OVERVIEW 2 2 2 4 INSTALLATION STEP 1 MOUNT MONITOR 2 2 2 5 INSTALLATION STEP 2 MOUNT GATEWAY 2 2 2 6 INSTALLATION STEP 3 WIRE SYSTEM COMPONENTS 2 3 2 7 INSTALLATION ST...

Страница 3: ...e nozzle 1 3 Figure 1 4 HydroBlast CAN to Ethernet IP gateway 1 4 Figure 1 5 Protective Cage 1 4 Figure 2 1 Gateway Enclosure Dimensions 2 2 Figure 2 2 Gateway Enclosure Connections 2 3 Figure 3 2 1 C...

Страница 4: ...shdown system and may not have the opportunity to visit the sites where the product is installed or intended to be installed It is the responsibility of the professional installer described above to p...

Страница 5: ...PA National Fire Protection Association A Ampere V Volts AC Alternating Current VAC Volts AC AWG American Wire Gauge VDC Volts DC cm Centimeters DC Direct Current ft Feet GPM Gallons Per Minute LPM Li...

Страница 6: ...ould be operated from a remote location Do not needlessly expose personnel to dangerous fire conditions Open water valves supplying this equipment slowly so that piping fills slowly thus preventing po...

Страница 7: ...SCRIPTION The HydroBlast washdown system is an automatic remote controllable industrial washdown monitor cannon system which performs wash operations with high flow pressurized water based on customer...

Страница 8: ...can be controlled by hardwired input devices via CAN bus The monitor may be powered with 12 24VDC High power permanent magnet variable speed DC gear motors that drive the horizontal and vertical motio...

Страница 9: ...ion The CCM also provides electrical power connection points for input power to the motors Electronics in the CCM enclosure are fully potted with epoxy to prevent dust and water contact 1 6 NOZZLE The...

Страница 10: ...ctLogix SLC5 05 MicroLogix and other PLC controls HMI and other devices supporting Ethernet IP CIP ModbusTCP messaging and connections Figure 1 4 shows the HydroBlast CAN to Ethernet IP gateway Figure...

Страница 11: ...cessary materials and tools 2 2 1 STANDARD SYSTEM CONTENT Monitor with onboard control module motor and harnesses Nozzle Gateway 2 2 2 ADDITIONAL ITEMS The additional items below are available separat...

Страница 12: ...e onto 2 5 NPT monitor outlet thread and tighten 2 5 INSTALLATION STEP 2 MOUNT GATEWAY If Gateway enclosure will be use follow the steps below to install the gateway enclosure Mark and pre drill holes...

Страница 13: ...ready for Normal Operation The HydroBlast cannon is typically pre calibrated from the factory and will default the user programmable limits to the maximum safe operation of the cannon only limited by...

Страница 14: ...S NO Has stow position been set YES NO Has programming stop limits been set YES NO Are LED indication lights on Cannon onboard control all green YES NO Is correct power cable being used YES NO Is the...

Страница 15: ...unts Top Mechanical Limit 135 45 Pointing Up Figure 3 2 1 Cannon Horizontal Coordinate System Figure 3 2 2 Cannon Vertical Coordinate System The cannon position status is reported in tenths of a degre...

Страница 16: ...ibility that when the cannon is commanded to go to the 45 degree mark it will travel into the lower vertical mechanical stop at around the 48 degree mark If this occurs reset the monitor to its calibr...

Страница 17: ...urred If the reason that the Jog command ended was due to hitting a limit a Command Error bit is also set All status bits are cleared upon executing a new command 3 3 3 GOTO MODE In Goto Mode you can...

Страница 18: ...and is shown here below This buffer is designed to be sent to the gateway where it will be converted into an 8 byte CAN message and sent to the cannon Note that PLC Big Endian 16 bit integers are tran...

Страница 19: ...uration whenever you set a jog bit to true then the cannon will start to move at the programmed speed If you modify the horizontal speed field then the move will change speed dynamically This mode is...

Страница 20: ...r vertical axis the Command in Process bit will be set In the case where the command would result in no movement for example setting all the Jog bits to zero the Command in Process will be cleared and...

Страница 21: ...al move the appropriate distance and speed is calculated to make the horizontal and vertical portions of the moves to complete at the same time Hitting a user or hard limit will stop the movement for...

Страница 22: ...s set to 0xb3ff and the source element field points to the aboveTorque Limit Command Buffer The following is a list ofTorque Limit Commands that can be executed TorqueLimit Command Operational Descrip...

Страница 23: ...the desired speed of 0 5 degrees second is meet Now repeat these same jog commands but with the maximum speed 15 degrees second programmed into the Jog commands Slowly increase the PWM slope from 0 i...

Страница 24: ...LED Indication State Interpretation Power LED ON Cannon is powered Horizontal LED ON Cannon received command from remote control or joystick control to move left or right Vertical LED ON Cannon recei...

Страница 25: ...ing nozzle flow test inspect monitor swivel joints for leaks Inspect all exposed wiring for signs of damage If protective cage is used use the appropriate tool to clean the cage of dust build up Note...

Страница 26: ...low provides descriptions and part numbers available for the HydroBlast wash system Part Number Description 00007100MG HydroBlast Wash System including brass monitor with DN80 flange onboard control b...

Страница 27: ...current 5A Stall current 10A Current trip point 8A Material Silicon Bronze Flange DN80 Table E per AS2129 2 5 inlet ID Seals Industrial grade bearing seals Weight 63 LBS Operating temperature range 4...