TROUBLE SHOOTING AND MAINTENANCE

Orifice Assy

Housing Assy

Pedestal

Bubbler Locknut

Drain

Retaining Nut

Regulator Holder

Regulator

Fountain Body-Short

Fountain Body-Long

Bottom Cover Plate-Short

Bottom Cover Plate-Long

Upper Panel

Lower Panel

Screw - #10-24 X .50 PHTC

Strainer

Hex Nut

Poly Tubing (Cut To Length)

Regulator Mounting Bracket-Long Ftn

Solenoid Mounting Bracket

Regulator  Mounting Bracket-Short Ftn

Sensor Support  Mounting Bracket

Solenoid Valve Assy

Power Cord

Sensor Assy

Screw - #8-18 X .37 HHSM

Nut - Regulator

Hex Nut #10-32

Push Button

Push Button Sleeve

Strain Relief

Spacer - 1/2 X .44

Set Screw #6-32 X .31"

Screw - #10-24 X .38 PHTC

Screw - 1/4-20 X .38 HHTC

Elbow - 1/4 X 1/4

Tee - 1/4

Fitting - 1/4 NPTF X 1/4 O.D.

Screw - #10-24 X .62 HHMS

Screw- 5/16-18 X .75

Hex Nut - 5/16-18

Set Screw #6-32 X .12"

A54874

56011C

55997C

75580C

LK464

15005C

50986C

61313C

55000604

27623C

55000661

55000665

26839C

26833C

112627543890

55996C

40045C

56092C

22525C

22526C

27057C

27240C

31272C

31376C

31384C

38417001

56082C

70016C

45662C

45663C

50203C

51409C

70022C

70208C

70256C

70817C

70682C

75507C

111008343890

111577243890

111577343890

70023C

FIG. 7

FIG. 6

SEE FIG. 8

5

11, 15

9

SEE FIG. 5

10

12, 15

1. 

Orifice Assy:

  Minerals deposits on orifice can cause water flow to spurt or not

    regulate.  Mineral deposits may be removed from the orifice with a small round

    file not over 1/8" diameter or a small diameter wire.  

CAUTION:

  Do not file or

    cut orifice materials.

2. 

Stream Regulator:

  If orifice is free of material deposits regulate water flow

    according to instructions on page 3.

3. 

Sensor Control:

  The sensor has a 2 second delay time.  If sensor fails to

    operate valve mechanism or operates erratically, check the following:

    a) Ensure there are no obstructions within a 40 inch radius from the front of

        fountain.

    b) Check wire connections at the solenoid valve and at the sensor.

     

CAUTION:

  Make sure unit is unplugged before checking any wiring.

    c) Ensure proper operation of solenoid valve.  If there is an audible clicking

       sound yet no water flows, look for an obstruction in the valve itself or

        elsewhere in the water supply line. 

WARNING:

  Do not expose sensor to

       direct sunlight.

4. 

Sensor Range Adjustment:

  The electronic sensor used in this fountain is

    factory pre-set for a "visual" range of 36 inches.  If actual range varies greatly

    from this, or a different setting is desired, follow the range adjustment

     procedure below:

    a) Remove bottom cover of fountain.

    b) Remove sensor by removing washers and nuts that secure sensor on studs.

    c) Locate range adjustment screw between the red lenses of the sensor, then

        with a small tip screwdriver, rotate the range adjusting screw clockwise to

        increase range or counter-clockwise to decrease range.  1/4 turn of screw is

        equal to approximately 12 - 18 inches of range.

        

CAUTION:

 Complete range of sensor (24 - 46 inches) is only one turn of the

        adjusting screw.

    d) Remount sensor on studs and replace bottom cover.

40, 41

40, 41

3

2

4

NOTE:  

WHEN INSTALLING

REPLACEMENT BUBBLER

AND PEDESTAL, TIGHTEN

NUT (ITEM 4) ONLY TO HOLD

PARTS SNUG IN POSITION.

  DO

NOT OVER TIGHTEN.

1

FIG. 8

29

30

17

6

8

7

33

21

23

26

FIG. 9

18

18

ERO28C

ERO28RAC

42

www.DrinkingFountainDoctor.com          800-518-5388

All manuals and user guides at all-guides.com

Содержание Soft Sides FLEXI-GUARD ERO28C C Series

Страница 1: ... TO WATER LINES ISACOMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTOAFOUNTAIN CREATINGAN ELECTROLYSIS WHICH CAUSESA METALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION ISAVOIDABLE BY USING THE PROPER MATERIALSAS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF...

Страница 2: ...C PAGE 2 FIG 3 LEGEND A 1 4 O D TUBE CONNECT CHILLER WATER OUTLET B 3 8 O D TUBE CONNECT CHILLER WATER INLET SHUT OFF VALVE BY OTHERS C 1 1 4 TRAP FURNISHED D ELECTRICAL INLET ERO28C ERO28RAC All manuals and user guides at all guides com ...

Страница 3: ...g 1 4 O D poly tubing provided Insert one end into remaining outlet of the 1 4 tee and the other end into the regulator holder on push button fountain 10 Remove elbow from end of p trap and attach it to drain tube Re attach elbow to p trap and cut waste tube to required length using plumbing hardware and trap as a guide 11 Connect power cord of sensor to solenoid valve by running it through the ba...

Страница 4: ...file or cut orifice materials 2 Stream Regulator If orifice is free of material deposits regulate water flow according to instructions on page 3 3 Sensor Control The sensor has a 2 second delay time If sensor fails to operate valve mechanism or operates erratically check the following a Ensure there are no obstructions within a 40 inch radius from the front of fountain b Check wire connections at ...

Отзывы: