Elkay LZO Series Скачать руководство пользователя страница 6

Page 6

2000000557 (Rev. B - 06/22)

LZO8WSN_2A

B

C

A

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED 

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE 

PULLING IT OUT HELPS TO 

RELEASE TUBE

A

B

C

2.  Bubbler

: Mineral deposits on the orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a 

small round file not over 1/8” (3mm) diameter or small diameter wire.

DO NOT file or cut orifice material. Care must be taken not to damage the orifice(s).

3.  Ventilation

: Cabinet louvers and condenser fins should be periodically cleaned with a brush, air hose or vacuum cleaner. Cleaning should be         

one twice each year or more frequently if needed due to environment. Excess dirt or poor ventilation can cause no cold water and compressor 

cycling on the compressor overload protector.

4. 

Water Flow: Confirm proper water flow. If water flow is slow, inspect filter or inline strainer for restriction. Replace filter cartridge if required.        

Disassemble inline strainer and clean if required.

5. 

Lubrication: Motors are lifetime lubricated.

6. 

Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors 

which utilize o-ring water seal. To remove tubing from the fitting, relieve water pressure, 

push in on the gray collar before pulling on the tubing. To insert tubing, push tube straight 

into fitting until it reaches a positive stop, approximately 3/4” (19mm).

Figure 7

Service: Adjustments

1.  Temperature Control

: Factory set for 50°F water (+/- 5°) (10°C ± 2.8°) under normal conditions. For colder water, adjust screw on cold control 

clockwise (see Cooler Manual).

2. 

Water Stream Height: Stream height is factory set at 35 PSI (2.4 bar). If supply pressure varies greatly from this, adjust screw located on the 

right knee clearance area. CW adjustment will raise stream and CCW adjustment will lower stream. For best adjustment, stream should hit 

basin approximately 6-1/2” (165mm) from bubbler on the downward slope of the basin.

 

NOTE: If water does not flow or flows sporadically after a refrigeration cycle, turn cold control counterclockwise 1/4 turn.

3.  Stream Regulator:

 If orifice is clean, regulate flow as in “STARTUP” instructions above. If replacement is necessary, see parts list for correct 

regulator part number.

4. 

Water coming out of Bubbler continuously: Check the solenoid valve and the electric eye sensor. 

5.  Cooler Sensor Range Adjustment:

 The electronic sensor used in this cooler is factory pre-set for a “visual” range of 36 inches (914 mm). If 

actual range varies greatly from this or a different setting is desired, follow the range adjustment procedure below:

 

- Using a small tip screwdriver, locate range adjustment screw through the small hole between the sensor lenses. Turn this screw clockwise 

to increase range and counterclockwise to decrease range.

6.  Sensor Control:

 If sensor fails to operate valve mechanism or operates erratically, check the following:

- Ensure there are no obstructions within a 40 inch (1016mm) radius in front of cooler.

- Check wire connections at the solenoid valve and sensor. 

 

- Ensure proper operation of solenoid valve. If there is an audible clicking sound yet no water flows, look for an obstruction in the valve itself 

or elsewhere in the water supply line.

Service: Inspection/Cleaning

• 

Inspect Bottle Filler and Cooler twice each year for proper operation and performance.

• 

Inspection of the unit will require disconnecting electrical supply, removal of panels, etc. and reassembly and return to service practices.

1.  Cleaning

: Warm, soapy water or mild household cleaning products can be used to clean the exterior panels of the EZ coolers. Extra caution 

should be used to clean the mirror finished stainless steel panels. They can be easily scratched and should only be cleaned with mild soap and 

water or Windex glass cleaner and a clean, soft cloth Use of harsh chemicals or petroleum based or abrasive cleaners will void the warranty.

Service

• 

Safety Glasses

•  Protective gloves

For proper and safe servicing, please read these instructions completely.

DANGER

• 

All Service and Maintenance must be performed by an authorized service person. 

 

Service Technician must have specialized training before servicing systems containing flammable refrigerants. 

 

Personnel who have not received certification for completing the Hydrocarbon Training Program and passed the examination, or received  

equivalent training and certification, shall not service any system containing flammable refrigerants.

• 

Disconnect electrical supply to the unit before any service work to reduce risk of electrocution. 

• 

Shut off water supply serving the unit before any service work to reduce risk of water damage.

CAUTION

•  To prevent scratching the basin, place a towel or soft cloth over the entire basin when working above it.
•  Do not puncture tubing.
• 

No open flame or sparks during servicing or repair.

• 

Repair and Disposal must be carried out by trained service personnel.

•  Place in a well ventilated area to prevent accumulation of refrigerant.
• 

Tools/Items required but not provided, for Servicing:

CAUTION

• 

Hex drives

• 

5/32” (4mm) Hex Key Flat blade Screwdriver 

CAUTION

Complete range of sensor (24-46 inches/610-1168mm) is only one turn of the adjusting screw.

CAUTION

Make sure unit is unplugged before checking any wiring.

Содержание LZO Series

Страница 1: ...ctions and safety precautions in this manual can result in serious injury or death After installation keep these instructions in a safe location for future reference Electric supply must be identical...

Страница 2: ...it is necessary to cut the drain loosen the screw at the black rubber boot and remove tube check for leaks after re assembly Installation Water Line connection 1 Ensure Mains Water Supply has Water Sh...

Страница 3: ...nplated copper tube B Recommended Location for Waste Outlet 1 1 4 19mm O D drain C 1 1 4 19mm Trap not furnished D Unit equipped with IEC C14 socket Cord not provided Electrical outlet per local code...

Страница 4: ...er shroud Replace all four screws previously removed 6 Once unit has been inspected for leaks and any leaks found corrected plug Bottle Filler and unit into wall Be sure to reinstall fuse to the circu...

Страница 5: ...t back to bottle count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REF...

Страница 6: ...n this cooler is factory pre set for a visual range of 36 inches 914 mm If actual range varies greatly from this or a different setting is desired follow the range adjustment procedure below Using a s...

Страница 7: ...g the retaining screw To remove the bubbler loosen locknut from the underside of the bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick Connect Fittings section in...

Страница 8: ...339 40319C 1100000002 2000000621 Hanger Bracket Basin Stainless Steel Sensor EE Compressor Serv Pack Tubing Poly Cut To Length Assy Shroud Upper Front Side Push Drier Kit Drain Replacement EZ Brkt Tub...

Страница 9: ...d Suite 200 Downers Grove IL 60515 U S A 630 574 8484 www elkay com Figure 12 23 21 1 8 14 25 19 24 5 See Figure 9 Figure 11 Sensor Eye Adjustment screw 18 2 See Figure 12 19 13 10 19 17 9 19 20 15 7...

Отзывы: