Elkay LZO Series Скачать руководство пользователя страница 4

Page 4

2000000557 (Rev. B - 06/22)

LZO8WSN_2A

Operation: Start-Up

Figure 6

BOTTLE FILLING UNIT

WALL MOUNTING PLATE

1. 

Remove two (2) mounting screws with 5/32” (4mm) Allen wrench 

holding top cover to Bottle Filler (see Fig 3). Remove top cover. 

Note:  Do  not  discard  mounting  screws;  they  will  be  needed  to 

reinstall top cover.

2.  Remove wall mounting plate from Bottle Filler. Place wall plate 

against wall on top of basin. Center the wall plate side to side with 

the basin. Mark the six (6) mounting holes with a pencil (See Fig 1).

3. 

Remove wall mounting plate from wall. NOTE: Mounting plate MUST 

be  supported  securely. Add  fixture  support  carrier  if  wall  will  not 

provide adequate support.

4. 

Install wall mounting plate to wall using six (6) 7/16” (11mm) 

obround mounting holes (mounting bolts not included)  

(See Fig 2). Use appropriate fasteners for your wall type.

5. 

Lay Bottle Filler on water cooler basin and cut insulation from tube 

even with bottom of gasket, remove this insulation from the 3/8” 

(10mm) tube, but do not discard. Feed the power cord (not provided) 

and waterline through the hole on top of water cooler. NOTE: To 

prevent scratching the basin place a towel or soft cloth over the 

entire basin when working above it.

6. 

Install gasket on bottom of bottle filler tower with gasket support 

bracket & (2) screws (See Fig 5).

7.  Feed power cord & 3/8” (10mm) water line through hole in tower/

basin gasket (See Fig 4).

8. 

Once Bottle Filler is installed on wall plate tabs, water line, wire(s) 

and power cord are installed properly, push top of Bottle Filler toward 

wall and line up top cover two (2) holes.

1. 

Turn on the building water supply and check all connections for leaks.

2. 

Ensure unit is plugged into electrical supply. Unit must have electrical power to 

have water flow.

WARNING

3. 

Purge air from all water lines by: 

• 

Activating the water flow with hands free sensor of the cooler/fountain. 

NOTE:

 Steady stream of water assures all air is removed.

4. 

Recheck all water and drain connections with water flowing through system.

5.  Replace the lower panel ensuring that the metal wrapper is secured inside of the 

upper shroud. Replace all four screws previously removed.

6. 

Once unit has been inspected for leaks and any leaks found corrected, plug Bottle 

Filler and unit into wall. Be sure to reinstall fuse to the circuit or switch the circuit 

breaker back to the “ON” position.

7.  Once power is applied to Bottle Filler, the GREEN LED light should illuminate 

showing good filter status along with the LCD Bottle Counter.

8. 

Verify proper dispensing by placing cup, hand, or any opaque object in front of 

sensor area and verify water dispenses. Note: The first initial dispenses might 

have air in line which may cause a sputter. This will be eliminated once all air is 

purged from the line.

9. 

Once unit tests out, install Lower Panel back on water cooler. Unit is now ready 

for use.

Installation: Bottle Filler Mounting

Figure 2

Figure 3

Figure 4

TOP COVER

7/16” (11mm) BOLT  HOLES 

FOR  FASTENING UNIT

UNIT CENTER LINE

MOUNTING 

SCREWS

29

Figure 5

BRACKET & SCREWS

9.  Reinstall Top Cover on Bottle Filler (See Fig. 3) with two mounting screws from step 1 above.  

Caution: Do not over tighten screws.

10. 

Install remaining tube insulation to the water line from bottle filler, connect Bottle Filler waterline inside of 

the water cooler by connecting the 3/8” (10mm) water line to the tee.

11. 

Install filter cartridge, remove filter from carton, remove protective cap, attach filter to filter head by firmly 

inserting  into  head  and  rotating  filter  clockwise.  NOTE:  If  existing  plumbing  rough  in  locations  (Drain, 

Water In, and Electric Supply) do not allow the filter to be mounted inside the cooler cabinet the filter can 

be installed horizontally below the unit. A retrofit kit is available to mount the filter beneath the cooler.

 

NOTE: If the filter relocation kit part number 

98568C is used on single cooler unit, the cooler is no longer 

ADA compliant.

12. 

Turn water supply on and inspect for leaks. Fix all leaks before continuing.

Installation: Electrical connection

1. 

Ensure power supply is identical in voltage, cycle and phase to that specified 

on the cooler data plate. NEVER wire compressor directly to the power supply.

BLK

COLD CONTROL

GND

FAN

WHT

RED

SENSOR

WHT

BLK

2

3

1

5

6

M

S

C

3

1

2

SOLENOID

VALVE

GREEN

RELAY

MALE TERMINAL ON 

WHITE SHORT LEAD 

ON POWERCORD

GND

GND

OVERLOAD

EMI FILTER

COMPRESSOR

Wiring Diagram

12

Содержание LZO Series

Страница 1: ...ctions and safety precautions in this manual can result in serious injury or death After installation keep these instructions in a safe location for future reference Electric supply must be identical...

Страница 2: ...it is necessary to cut the drain loosen the screw at the black rubber boot and remove tube check for leaks after re assembly Installation Water Line connection 1 Ensure Mains Water Supply has Water Sh...

Страница 3: ...nplated copper tube B Recommended Location for Waste Outlet 1 1 4 19mm O D drain C 1 1 4 19mm Trap not furnished D Unit equipped with IEC C14 socket Cord not provided Electrical outlet per local code...

Страница 4: ...er shroud Replace all four screws previously removed 6 Once unit has been inspected for leaks and any leaks found corrected plug Bottle Filler and unit into wall Be sure to reinstall fuse to the circu...

Страница 5: ...t back to bottle count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REF...

Страница 6: ...n this cooler is factory pre set for a visual range of 36 inches 914 mm If actual range varies greatly from this or a different setting is desired follow the range adjustment procedure below Using a s...

Страница 7: ...g the retaining screw To remove the bubbler loosen locknut from the underside of the bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick Connect Fittings section in...

Страница 8: ...339 40319C 1100000002 2000000621 Hanger Bracket Basin Stainless Steel Sensor EE Compressor Serv Pack Tubing Poly Cut To Length Assy Shroud Upper Front Side Push Drier Kit Drain Replacement EZ Brkt Tub...

Страница 9: ...d Suite 200 Downers Grove IL 60515 U S A 630 574 8484 www elkay com Figure 12 23 21 1 8 14 25 19 24 5 See Figure 9 Figure 11 Sensor Eye Adjustment screw 18 2 See Figure 12 19 13 10 19 17 9 19 20 15 7...

Отзывы: