![Elkay LZO Series Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/elkay/lzo-series/lzo-series_installation-and-user-manual_2391316004.webp)
Page 4
2000000557 (Rev. B - 06/22)
LZO8WSN_2A
Operation: Start-Up
Figure 6
BOTTLE FILLING UNIT
WALL MOUNTING PLATE
1.
Remove two (2) mounting screws with 5/32” (4mm) Allen wrench
holding top cover to Bottle Filler (see Fig 3). Remove top cover.
Note: Do not discard mounting screws; they will be needed to
reinstall top cover.
2. Remove wall mounting plate from Bottle Filler. Place wall plate
against wall on top of basin. Center the wall plate side to side with
the basin. Mark the six (6) mounting holes with a pencil (See Fig 1).
3.
Remove wall mounting plate from wall. NOTE: Mounting plate MUST
be supported securely. Add fixture support carrier if wall will not
provide adequate support.
4.
Install wall mounting plate to wall using six (6) 7/16” (11mm)
obround mounting holes (mounting bolts not included)
(See Fig 2). Use appropriate fasteners for your wall type.
5.
Lay Bottle Filler on water cooler basin and cut insulation from tube
even with bottom of gasket, remove this insulation from the 3/8”
(10mm) tube, but do not discard. Feed the power cord (not provided)
and waterline through the hole on top of water cooler. NOTE: To
prevent scratching the basin place a towel or soft cloth over the
entire basin when working above it.
6.
Install gasket on bottom of bottle filler tower with gasket support
bracket & (2) screws (See Fig 5).
7. Feed power cord & 3/8” (10mm) water line through hole in tower/
basin gasket (See Fig 4).
8.
Once Bottle Filler is installed on wall plate tabs, water line, wire(s)
and power cord are installed properly, push top of Bottle Filler toward
wall and line up top cover two (2) holes.
1.
Turn on the building water supply and check all connections for leaks.
2.
Ensure unit is plugged into electrical supply. Unit must have electrical power to
have water flow.
WARNING
3.
Purge air from all water lines by:
•
Activating the water flow with hands free sensor of the cooler/fountain.
NOTE:
Steady stream of water assures all air is removed.
4.
Recheck all water and drain connections with water flowing through system.
5. Replace the lower panel ensuring that the metal wrapper is secured inside of the
upper shroud. Replace all four screws previously removed.
6.
Once unit has been inspected for leaks and any leaks found corrected, plug Bottle
Filler and unit into wall. Be sure to reinstall fuse to the circuit or switch the circuit
breaker back to the “ON” position.
7. Once power is applied to Bottle Filler, the GREEN LED light should illuminate
showing good filter status along with the LCD Bottle Counter.
8.
Verify proper dispensing by placing cup, hand, or any opaque object in front of
sensor area and verify water dispenses. Note: The first initial dispenses might
have air in line which may cause a sputter. This will be eliminated once all air is
purged from the line.
9.
Once unit tests out, install Lower Panel back on water cooler. Unit is now ready
for use.
Installation: Bottle Filler Mounting
Figure 2
Figure 3
Figure 4
TOP COVER
7/16” (11mm) BOLT HOLES
FOR FASTENING UNIT
UNIT CENTER LINE
MOUNTING
SCREWS
29
Figure 5
BRACKET & SCREWS
9. Reinstall Top Cover on Bottle Filler (See Fig. 3) with two mounting screws from step 1 above.
Caution: Do not over tighten screws.
10.
Install remaining tube insulation to the water line from bottle filler, connect Bottle Filler waterline inside of
the water cooler by connecting the 3/8” (10mm) water line to the tee.
11.
Install filter cartridge, remove filter from carton, remove protective cap, attach filter to filter head by firmly
inserting into head and rotating filter clockwise. NOTE: If existing plumbing rough in locations (Drain,
Water In, and Electric Supply) do not allow the filter to be mounted inside the cooler cabinet the filter can
be installed horizontally below the unit. A retrofit kit is available to mount the filter beneath the cooler.
NOTE: If the filter relocation kit part number
98568C is used on single cooler unit, the cooler is no longer
ADA compliant.
12.
Turn water supply on and inspect for leaks. Fix all leaks before continuing.
Installation: Electrical connection
1.
Ensure power supply is identical in voltage, cycle and phase to that specified
on the cooler data plate. NEVER wire compressor directly to the power supply.
BLK
COLD CONTROL
GND
FAN
WHT
RED
SENSOR
WHT
BLK
2
3
1
5
6
M
S
C
3
1
2
SOLENOID
VALVE
GREEN
RELAY
MALE TERMINAL ON
WHITE SHORT LEAD
ON POWERCORD
GND
GND
OVERLOAD
EMI FILTER
COMPRESSOR
Wiring Diagram
12