LZO8WSN_2A

Operation: Bottle Filler BF12 Control Board Set-Up

VERIFY CONTROL BOARD  SOFTWARE

1) To verify the software program of the control board the unit will  

    need to be shut down and restarted. The chiller (if present) does 

    not need to be shut down and restarted.

2) The units lower panel must be open to access the power cord and 

    wall outlet.

3) Shut down the unit by unplugging the power cord from the wall

    outlet or switching off the circuit breaker to the unit.

4)  

Restart the unit by plugging the power cord back into the wall outlet.

5) Upon start up, the bottle count display will show the software 

    designation of BF12.

ACCESSING THE PROGRAMMING BUTTON

1)   To access the program button 

remove the top cover of the bottle-

    filler. Remove the two (2) screws holding top cover to bottle-

    filler with a 5/32” (4mm) allen wrench.  Remove top cover. Do  

         

    not discard mounting screws, they will be needed to reinstall the  

     

    top cover

 

after programming operations are completed. The  

    

programming button is located at the top right side of the unit on  

     

    

the control board.

RESET THE FILTER MONITOR

1) Instructions apply to filtered units only.

2) Depress the program button for approximately 2 seconds until 

    the display changes then release. The display will change and 

    scroll through two messages:

       “RST FLTR” – Reset Filter Monitor

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

3) When the display changes to “RST FLTR”, depress the button 

    again. The display will change to show “FLTR =”. Depress the

    button again and the display will show “FLTR =0”

4) The Green LED should be illuminated indicating that the visual 

    filter monitor has been reset.

 SETTING RANGE OF THE IR SENSOR WHERE APPLICABLE

1) Depress the program button for approximately 2 seconds until 

    the display changes then release. The display will change and 

    scroll through two messages:

     “RST FLTR” – Reset Filter Status LED

    “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

2) When the display changes to “SETTINGS”, depress the button 

    again. The display will change to show

    “RNG SET” -  Range set for IR sensor.

    “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

    “FLT SIZE” - Select filter capacity

    “RST BCNT” - Reset bottle count

3)  When display shows “RNG SET” push program button once the 

    display will show current value (can be 1 – 10) e.g. “RNG = 3”.

4) Once display shows current value push the program button to 

    scroll through value of 1 – 10. Select the desired range setting, 

  "1" being closest to sensor and "10" being farthest away.

5) Once range is selected allow approximately 4 seconds to pass and

    then the display will go back to bottle counter and be in run mode.

6)  Test bottle filler by placing bottle or hand in front of sensor to 

    make sure water is dispensed.

SETTING UNIT TYPE

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will

 change and scroll 

    through two messages:

     

“RST FLTR” – Reset Filter Status LED

    “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

2)  

When the display changes to “SETTINGS”, depress the button again.  

      The display will change to show

     

  “RNG SET” -  Range set for IR sensor.

       “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

Continued from below:       

       “FLT SIZE” - Select filter capacity

       “RST BCNT” - Reset bottle count

3)  

When display shows “UNIT TYPE” push program button once the

    display will show current value. 

 

Can be REFRIG or NON-RFRG

4) Push button once to change value. Once value is  

  selected the           

    display will show the new value. 

 

(Can be REFRIG or NON-RFRG)  

     

“REFRIG“ - stands for refrigerated product. In this setting the flow  

    rate is estimated at 1.0 gallon per minute (3.8 lpm).

     

“NON-RFRG“ - stands for non refrigerated product. In this setting the  

     flow rate is estimated at 1.5 gallons per minute (5.7 lpm). Both 

 

    “REFRIG“ and “NON-RFRG“ simulate 

  

1 bottle equal to 

 

    20 oz (590 ml).

5)  

Allow approximately 4 seconds to pass and the display will return to         

       bottle counter and be in run mode.

    

 RESETTING BOTTLE COUNT

  NOTE: Once the bottle count is reset to zero there is no way to 

  return to the previous bottle count.

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll

    through two messages:

     “RST FLTR” – Reset Filter Status LED

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll  

    through the two messages above for three cycles and then default  

    back to bottle count and be back in run mode.

2) When the display changes to “SETTINGS”, depress the button  

    again. The display will change to show:

     

 “RNG SET”-  Range set for IR sensor.

      “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

       

“FLT SIZE” - Select filter capacity

      “RST BCNT” - Reset bottle count

    If the button is not pushed again the display will scroll through the 

    four messages above for three cycles and return to run mode.

3)  

When display shows “RST BCNT” push program button once the

    display will show current value, e.g. “0033183”.

4) Once display shows current value push the program button once 

    more to reset back to 0. The display will show BTLCT = 0 for 

 

    approximately 2 seconds and then return to run mode showing 

    00000000 bottles. 

5)  Testing the bottle counter:

    REFRIG units: Place bottle or hand in front of sensor for 

    approximately 9 seconds to see bottle counter count 00000001, 

    (This is based on filling a 20 oz (590 ml) bottle).

    NON-RFRG units: Place bottle or hand in front of sensor for 

  approximately 6 seconds to see bottle counter count 00000001,

    (This is based on filling a 20 oz (590 ml) bottle).

    

 SETTING FILTER CAPACITY

1) Depress the program button for approximately 2 seconds until the

     display changes then release. The display will

 change and scroll 

     through two messages:

     

“RST FLTR” – Reset Filter Status LED

     

“SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

2) When the display changes to “SETTINGS”, depress the button 

    again. The display will change to show:

     

“RNG SET“ -  Range set for IR sensor.

     “UNIT TYP“ - Type of unit (REFRIG or NON-RFRG)

      

“FLT SIZE” - Select filter capacity

     “RST BCNT“ - Reset bottle count

    If the button is not pushed again the display will scroll through the 

    four messages above for three cycles and return to run mode.

3)  

When display shows “FLT SIZE” push program button once. The 

    display will show current value. Can be 3000GAL or 6000GAL.

4) Push program button again to display the desired “FLT SIZE”. 

5) Allow approximately 4 seconds to pass and the display will return to 

    bottle counter and be in run mode.

Содержание LZO Series

Страница 1: ...ctions and safety precautions in this manual can result in serious injury or death After installation keep these instructions in a safe location for future reference Electric supply must be identical...

Страница 2: ...it is necessary to cut the drain loosen the screw at the black rubber boot and remove tube check for leaks after re assembly Installation Water Line connection 1 Ensure Mains Water Supply has Water Sh...

Страница 3: ...nplated copper tube B Recommended Location for Waste Outlet 1 1 4 19mm O D drain C 1 1 4 19mm Trap not furnished D Unit equipped with IEC C14 socket Cord not provided Electrical outlet per local code...

Страница 4: ...er shroud Replace all four screws previously removed 6 Once unit has been inspected for leaks and any leaks found corrected plug Bottle Filler and unit into wall Be sure to reinstall fuse to the circu...

Страница 5: ...t back to bottle count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REF...

Страница 6: ...n this cooler is factory pre set for a visual range of 36 inches 914 mm If actual range varies greatly from this or a different setting is desired follow the range adjustment procedure below Using a s...

Страница 7: ...g the retaining screw To remove the bubbler loosen locknut from the underside of the bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick Connect Fittings section in...

Страница 8: ...339 40319C 1100000002 2000000621 Hanger Bracket Basin Stainless Steel Sensor EE Compressor Serv Pack Tubing Poly Cut To Length Assy Shroud Upper Front Side Push Drier Kit Drain Replacement EZ Brkt Tub...

Страница 9: ...d Suite 200 Downers Grove IL 60515 U S A 630 574 8484 www elkay com Figure 12 23 21 1 8 14 25 19 24 5 See Figure 9 Figure 11 Sensor Eye Adjustment screw 18 2 See Figure 12 19 13 10 19 17 9 19 20 15 7...

Отзывы: