Elkay LZO Series Скачать руководство пользователя страница 2

Page 2

2000000557 (Rev. B - 06/22)

LZO8WSN_2A

Installation

For correct and safe installation, please read these instructions completely.

• 

All Installation work must be performed by an authorized service person.

• 

Disconnect electrical supply serving the Installation area to reduce risk of electrocution. Do not puncture the refrigerant tube.

•  Unit not suitable for installations where water jets could be used. 

DANGER

WARNING

• 

Shut off water supply serving the Installation area to reduce risk of water damage.

• 

Ensure proper ventilation by maintaining clearance from cabinet louvers to wall on each side of Cooler as specified in Rough-In.

• 

Never wire compressor directly to electrical supply.

• 

Thoroughly flush all water lines and fittings of all foreign matter before connecting to Cooler.

• 

Warranty is void if Installation is not made in accordance with current Manufacturing instructions.

CAUTION

• 

Water Shut-off Valve with 3/8” (9.5mm) compression outlet

• 

Waste Trap (non-metallic)

• 

Safety Glasses

Installation: Cooler Mounting

1. 

Remove Hanger Bracket fastened to back of cooler by removing one (1) screw.

2. 

Mount Hanger Bracket as shown in Figure 1.

NOTE:

 Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. Anchor hanger     

securely to wall using all six (6) 1/4” (6mm) diameter mounting holes.

3. 

Hang Cooler on the Hanger Bracket. Be certain the Hanger Bracket is engaged properly in the slots on the cooler back as shown in Figure 1.

4. 

Remove the four (4) screws holding the lower front panel at the bottom of cooler. Remove the front panel by pulling straight down and set 

aside.

5.  Connect water inlet line. Install trap. Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that 

the end of the waste line fits into the trap. Assemble the slip nut and gasket to the trap and tighten securely.

IMPORTANT:

 If it is necessary to cut the drain, loosen the screw at the black rubber boot and remove tube, check for leaks after re-assembly.

Installation: Water Line connection

1. 

Ensure Mains Water Supply has Water Shut-off Valve with 3/8” (10mm) compression outlet. 

2. 

Connect loose end of supplied 3/8” (9.5mm) unplated copper tube to Water Shut-off Valve. Other end of tube should be connected to inlet of 

Filter head. If not connected, simply insert into inlet fitting on Filter head until positive stop – approximately ¾” (19mm). 

 

NOTE:

 If 3/8” (9.5mm) copper tube must be cut for proper fit, remove all burrs from the outside of tube and re-flush before use. 

3. 

Install filter cartridge. Remove filter from carton, remove protective cap, and attach filter to filter head by firmly inserting into head and rotating 

filter clockwise. 

 

IMPORTANT:

 DO NOT TURN ON WATER BEFORE INSTALLING BOTTLE FILLER. 

 

•  Hose-sets are not to be used for connecting to water mains.
• 

If inlet pressure is above 105 psig (0.72 Mpa), a pressure regulator must be installed in supply line. Any damage caused by reason of 

connecting this product to supply line pressure outside it’s rated pressure, is not covered by warranty.

• 

Tools/Items required but not provided. Tools must be compatible with flammable refrigerant.

CAUTION

• 

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory, or mental capabilities 

or lack of experience and knowledge if they have been given supervision or instructions concerning use of the appliance in a safe way and 

understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children 

without supervision.

• 

To prevent a metallic taste or increased metal content in the water due to an electrolysis process caused by electrical feedback from the 

grounding of electrical equipment to water supply and water waste mains, connect to these mains using non-conductive materials. The 

provided Filter meets this requirement.

• 

Protective Gloves

• 

Hex drives

• 

Fasteners for wall type

•  Flammable gas monitor
• 

5/32” (4mm) Hex Key

Содержание LZO Series

Страница 1: ...ctions and safety precautions in this manual can result in serious injury or death After installation keep these instructions in a safe location for future reference Electric supply must be identical...

Страница 2: ...it is necessary to cut the drain loosen the screw at the black rubber boot and remove tube check for leaks after re assembly Installation Water Line connection 1 Ensure Mains Water Supply has Water Sh...

Страница 3: ...nplated copper tube B Recommended Location for Waste Outlet 1 1 4 19mm O D drain C 1 1 4 19mm Trap not furnished D Unit equipped with IEC C14 socket Cord not provided Electrical outlet per local code...

Страница 4: ...er shroud Replace all four screws previously removed 6 Once unit has been inspected for leaks and any leaks found corrected plug Bottle Filler and unit into wall Be sure to reinstall fuse to the circu...

Страница 5: ...t back to bottle count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REF...

Страница 6: ...n this cooler is factory pre set for a visual range of 36 inches 914 mm If actual range varies greatly from this or a different setting is desired follow the range adjustment procedure below Using a s...

Страница 7: ...g the retaining screw To remove the bubbler loosen locknut from the underside of the bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick Connect Fittings section in...

Страница 8: ...339 40319C 1100000002 2000000621 Hanger Bracket Basin Stainless Steel Sensor EE Compressor Serv Pack Tubing Poly Cut To Length Assy Shroud Upper Front Side Push Drier Kit Drain Replacement EZ Brkt Tub...

Страница 9: ...d Suite 200 Downers Grove IL 60515 U S A 630 574 8484 www elkay com Figure 12 23 21 1 8 14 25 19 24 5 See Figure 9 Figure 11 Sensor Eye Adjustment screw 18 2 See Figure 12 19 13 10 19 17 9 19 20 15 7...

Отзывы: