Combination Refrigerated Drinking Fountain (Cooler) and Bottle Filling Station delivers chilled, clean potable drinking water. Top Bottle  

Filling section offer touchless activation to dispense water for bottles. While the bottom Water Cooler section, which houses the refrigeration 

and filtration systems, delivers a steady stream of water for direct drinking.

•  Electrical: 220-240 Vac, 50/60 Hz, (See Nameplate for Amperage), 

1 phase

•  Ambient Air Temperature: 50-89.6 °F (10-32 °C)
• 

Water Pressure: 20-105 psig (0.14-0.72 MPa)

• 

Maximum Water Temperature: 90 °F (32 °C)

• 

Sound Pressure level (A-weighted): < 70 dBA

•  Refrigerant: R290
•  Ingress Protection: IP20
• 

For Indoor Commercial Use only

• 

Water Inlet: 3/8”O.D. unplated copper tube

• 

Waste Water Outlet: 1-1/4” O.D. tube

DANGER

 

– Indicates death or serious injury will result if proper precautions are not taken.

WARNING

 – Indicates death, serious injury or property damage can result if proper precautions are not taken.

CAUTION

 – Indicates some injury or property damage may result if proper precautions are not taken.

Definitions

Authorized Service Personnel

 – Factory trained personnel or personnel having working knowledge of electrical, plumbing and 

machine (appliance) maintenance procedures. Service personnel must have specialized training for flammable refrigerants.

Safety

DANGER

• 

Please read these instructions completely before starting the installation or performing any service. Failure to follow the instructions                                       

and safety precautions in this manual can result in serious injury or death.

•  After installation, keep these instructions in a safe location for future reference.
• 

Electric supply must be identical in voltage, cycle, and phase to that specified on nameplate.

• 

Electrical supply may require Ground Fault Circuit Interrupter (GFCI) protection. Consult specific application and local codes. 

• 

A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules. This is to 

allow electrical disconnection of the unit from electrical supply after installation.

Description

Ratings

WARNING

•  Keep clear of obstructing all ventilation openings in the appliance enclosure or in the structure for building-in.
•  Place in a well ventilated area to prevent accumulation of refrigerant.
• 

No open flame or sparks during service or repair.

• 

For use with clean, clear potable drinking water only. Do not use with water that is microbiologically unsafe or of unknown quality without 

adequate disinfection before the system.

•  Installation and connection to water and electrical mains must be in compliance with local and national laws. 
• 

All Installation and Service work must be performed by trained / authorized service personnel. 

Notice: 

Coolers that use flammable refrigerants, such as R-600a (isobutane), R-290 (propane) will be marked with a 

 

specific symbol that notifies the servicer of the presence of these refrigerants. A service provider should review this marking 

and follow all instructions from the original equipment manufacturer.

Installation & Use Manual

Original Instructions

Model: EZO & LZO Series Sensor-Operated Water Coolers

Содержание LZO Series

Страница 1: ...ctions and safety precautions in this manual can result in serious injury or death After installation keep these instructions in a safe location for future reference Electric supply must be identical...

Страница 2: ...it is necessary to cut the drain loosen the screw at the black rubber boot and remove tube check for leaks after re assembly Installation Water Line connection 1 Ensure Mains Water Supply has Water Sh...

Страница 3: ...nplated copper tube B Recommended Location for Waste Outlet 1 1 4 19mm O D drain C 1 1 4 19mm Trap not furnished D Unit equipped with IEC C14 socket Cord not provided Electrical outlet per local code...

Страница 4: ...er shroud Replace all four screws previously removed 6 Once unit has been inspected for leaks and any leaks found corrected plug Bottle Filler and unit into wall Be sure to reinstall fuse to the circu...

Страница 5: ...t back to bottle count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REF...

Страница 6: ...n this cooler is factory pre set for a visual range of 36 inches 914 mm If actual range varies greatly from this or a different setting is desired follow the range adjustment procedure below Using a s...

Страница 7: ...g the retaining screw To remove the bubbler loosen locknut from the underside of the bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick Connect Fittings section in...

Страница 8: ...339 40319C 1100000002 2000000621 Hanger Bracket Basin Stainless Steel Sensor EE Compressor Serv Pack Tubing Poly Cut To Length Assy Shroud Upper Front Side Push Drier Kit Drain Replacement EZ Brkt Tub...

Страница 9: ...d Suite 200 Downers Grove IL 60515 U S A 630 574 8484 www elkay com Figure 12 23 21 1 8 14 25 19 24 5 See Figure 9 Figure 11 Sensor Eye Adjustment screw 18 2 See Figure 12 19 13 10 19 17 9 19 20 15 7...

Отзывы: