background image

Page 2

98980C  (Rev. J- 06/16)

LVRCDWS*A, *2A   LVRCTLDDWSC*A, *2A   LVRC8WS*1A, *2A, *3A   LVRCTL8WSC*1A, *2A, *3A

LVRC8WS Bottle Fillers

 are among the easiest to install on the market today. 

To insure you install these models easily and correctly,  PLEASE READ THESE 

SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR 

INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER 

APPLICABLE CODES. After installation, leave these instructions with the Fountain for 

future reference.

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER 

LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY 

FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, 

CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL 

CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS 

INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO 

ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THAT 

THE BOTTLE FILLING STATION AND WATER COOLER BE PROTECTED BY A GROUND FAULT CIRCUIT 

INTERRUPTER (GFCI).

TOOLS REQUIRED

BUT NOT PROVIDED:

SAFETY GLASSES

GLOVES

ELECTRIC DRILL

3/4” WRENCH OR CRECENT WRENCH

UTILITY KNIFE

TAPE MEASURE

PENCIL

CENTER PUNCH

1/2” SOCKET & RATCHET WRENCH

5/32” ALLEN WRENCH

 Uses HFC-134A refrigerant

 

Note: Danger! Electric shock hazard. Disconnect power before servicing unit.

Содержание EZH2O LVRC8WS

Страница 1: ...RCTL8WSC 1A 2A 3A LVRC8WS LVRC8WSJO LVRCTL8WS LVRCTL8WSJO Factory Prep EZH2O Bottle Filling Station and Cooler INSTALLATION CARE USE MANUAL IMPORTANT THIS IS AN INDOOR APPLICATION ONLY ALL SERVICE TO...

Страница 2: ...THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTEN...

Страница 3: ...m 5 1 8 131mm 48 1219mm O 5 16 8mm MOUNTING HOLES 3 PL 1 4 X 1 2 6mm X 13mm OBROUND HOLE 5 PL HANGER BRACKET 7 178mm 7 178mm 16 5 16 414mm 1 1 4 32mm 1 1 4 32mm Single Rough In Fig 1 LVRC8WS REDUCE HE...

Страница 4: ...98mm 31 15 16 811mm RIM HEIGHT 8 203mm 18 1 16 459mm 7 178mm 7 178mm 1 1 4 32mm 1 1 4 32mm 16 5 16 414mm O 5 16 8mm HOLES 3 PL 5 3 4 146mm 5 3 4 146mm 1 3 8 35mm 1 3 8 35mm 18 1 2 470mm 3 1 2 89mm 4 1...

Страница 5: ...was previously installed to the tee at the evaporator outlet 7a For Two Level Model Installations Install the 1 4 poly tubing and insulation from the outlet of the filter to the union on top of the ev...

Страница 6: ...from the sides of the Bottle Filler Remove the two 2 Pinned Torx Head Screws from the Top Cover remove the Top Cover The Bottle Filler may then be lifted up and off the Water Cooler The water line and...

Страница 7: ...cles and then default back to bottle count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT...

Страница 8: ...back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT T...

Страница 9: ...arts Kit Retro Filter Mounting Kit Electrical Package 220V Kit Solenoid Valve Replacement 220V Kit Filter Mounting Cover Kit Drain Pad Kit Button Assembly Kit Top Cover Replacement Kit Gasket VR BF To...