background image

Elkay Manufacturing Company 

(630) 574-8484 

Built-in Filtered Water Dispenser 

 

1000005232 (Rev. C - 05/19)

1. General Information

1.1  Installation, Care & User Manual

Read all instructions carefully BEFORE starting the 

installation and familiarize yourself with the various parts 

of this product.

This manual contains step-by-step installation, 

adjustment, and maintenance instructions for the Built-in 

Water Dispenser. Followed carefully, these instructions 

will result in an easy, trouble-free installation of this Elkay 

Manufacturing Company (Elkay) product. Additional use 

and care documents can be found on the Elkay website 

at 

http://www.elkay.com/support

.

Any deviations, additions, or deletions from the 

described methods, without the prior written approval of 

our Customer Care department, will void the warranty 

covering this product. 

Make sure the installation and use of this product meet all 

local, state, and federal plumbing and electrical codes.

Save these instructions for future reference.

WARNING

To avoid product or property damage, personal 

injury, or even possible death, carefully read, 

understand, and follow all the instructions in 

this Installation, Care, & Use Manual before installing 

this product.  

Improper installation, use, and/or maintenance of 

this product could cause a dangerous situation that 

results in injury or death.
Do not operate power tools unless you read and 

understand the instructions and warnings in this 

and all other applicable manuals. Proper use of tools 

and the products described in this guide is your 

responsibility.

Failure to follow these instructions could result in 

personal injuries, water damage, and other damage 

to floors, pipes, walls, and other portions of your 

home. 

1.2  Disclaimer

The information contained in this Installation, Care, & Use 

Manual is given free of charge. It is based upon technical 

data which we believe to be reliable and is intended 

for use by persons having knowledge of this technical 

area at their own discretion and risk. Elkay assumes no 

responsibility for results obtained or damage incurred 

from the use of this material either in whole or in part by 

the buyer.

1.3  Serial Number Location

Please use the serial number located on the inside right 

wall of the main enclosure, just above the junction box. 

Use this serial number when contacting us with questions 

concerning the installation of this product.

1.4  Contact Information

General Information 

Elkay Manufacturing Company 

2222 Camden Court 

Oak Brook, IL 60523

Phone: 630.574.8484 

Email: [email protected] 

Website: http://www.elkay.com 

USA/Canada Customer Care  

Phone: 800.476.4106  

Email: [email protected]

International Customer Care  

Phone: 630.575.4755  

Email: [email protected]

Installation Services 

Phone: 800.952.8064 

Email: [email protected]  

Website: http://www.elkay.com/contact-us/install 

1.5  Notice of Changes

The information, specifications, and illustrations in this 

manual are based on the information that was available 

at the time this material was written and can change at 

any time.

Dimensions are given in inches (") and millimeters (mm).

Содержание ezH2O Liv LBWD00 C Series

Страница 1: ...INSTALLATION CARE USER MANUAL Built in Filtered Water Dispenser ezH2O Liv ...

Страница 2: ......

Страница 3: ...rty Damage 5 3 Installation Preparation 5 3 1 General Information 5 4 Installation 6 4 1 Tools Required 6 4 2 Installer Supplied Parts Required 6 4 3 Critical Depth Dimensions 6 4 4 Mounting Height Dimensions 7 4 5 Water Dispenser Installation 7 4 5 1 Installing Water Dispenser into the Wall 7 4 5 2 Installing the Filter Box 8 4 5 3 Connecting the Water Lines 10 4 6 Connecting the Optional Catch B...

Страница 4: ... all other applicable manuals Proper use of tools and the products described in this guide is your responsibility Failure to follow these instructions could result in personal injuries water damage and other damage to floors pipes walls and other portions of your home 1 2 Disclaimer The information contained in this Installation Care Use Manual is given free of charge It is based upon technical da...

Страница 5: ...h Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de license L exploitation est autorisée...

Страница 6: ... are identified by the Safety Alert Symbol and followed by a signal word such as WARNING or CAUTION 2 3 Personal Safety WARNING These warnings indicate a potentially hazardous situation which if not avoided could result in serious injury or death Follow all instructions related to the installation and or maintenance of this product unit Personal Protection Be sure to use all personal protective eq...

Страница 7: ... 2 4 Property Damage NOTICE Inspect Before Cutting Make sure no electrical wiring or plumbing is present before cutting into a wall 3 Installation Preparation NOTICE The installation of this product requires electrical and plumbing connections that use specific skills and knowledge If you are unsure or not qualified to make these connections consult a qualified plumber electrician or installer for...

Страница 8: ...ed cable or plastic sheath NM B cable Electrical wire nuts appropriate size GFCI circuit connected into an electrical circuit 1 Water 3 8 flexible water tubing copper or plastic insulated Quarter turn shut off valve at the location of the water source 1 1 4 inch copper or plastic tubing if a remote filter is installed insulated 15 feet or less Optional Catch Basin Drain 1 1 4 P trap and related pa...

Страница 9: ...Note Item 2 According to most electrical codes the electrical box cannot be sealed inside a wall cavity with no access If the electrical connection is placed under the unit a user supplied removable wall cover will be required to access the junction box 4 5 Water Dispenser Installation There are several installation options available Water dispenser with attached filter box and filter Water dispen...

Страница 10: ...to the gang box b Tighten the wiring clamp to prevent the wire from being pulled out of the gang box c Connect black wire to supplied voltage line black wire and the white wire to neutral d Use installer provided wire nuts to insulate the connections e If required by code a green grounding screw can be used to connect a grounding wire inside the gang box f Reinstall the gang box cover NOTICE Do no...

Страница 11: ...o hold the unit in place Do not completely tighten the screws until the filter unit cover is installed and the fit between the water dispenser cover and the filter cover is checked Note Some side to side and up and down movement of the housing is capable to accurately align the filter unit with the water dispenser 3 Replace the filter unit cover and check the gap between the two covers Adjust the ...

Страница 12: ...coupling The type of 1 4 inch tubing copper or plastic should meet all local regulations and building codes This line should be insulated to prevent condensation Note Do not place the remote filter more than 15 feet from the water dispenser 3 Connect an installer supplied 3 8 inch water supply tube to the quarter turn shutoff valve as shown The type of tubing copper or plastic should meet all loca...

Страница 13: ... the centering dimple as a guide to center the hole saw Note Do not use a 1 1 8 inch hole saw as this will make the opening too large 3 Place a small amount of plumbers putty around the lip of the strainer flange and insert it into the hole If the flange does not fit carefully open the size of the hole 4 Install the O ring over the strainer threads 5 Thread the strainer into the drain adapter Need...

Страница 14: ...1 1 4 inch PVC pipe 9 Install the filter 10 Connect the drain adapter into the household waste drain pipe If the p trap is located inside a sealed walled it must have permanently glued joints If the p trap is in an accessible location a standard non glued p trap is acceptable Note Whichever installation method is used it must meet local standards and building codes 11 Install metal cover Do not in...

Страница 15: ...d in the water chiller manual The standard installation of the built in water dispenser supplies filtered water at the ambient temperature of the water supply that comes into the unit This temperature can vary greatly depending on the location of the incoming water line Follow the installation instructions that come with the water chiller A filter unit must also be installed prior to the chiller a...

Страница 16: ...d 66 percent of its life and will need to be changed soon When this indicator light comes on a replacement filter should be ordered The right most red light will illuminate in red and indicates that the filter should be changed FILTER LIFE PLASTIC BOTTLES SAVED 9 Once the installation is complete the water has been turned on and any trapped air has been bled from the system re check for any water ...

Страница 17: ... water that leaks out of the filter when it is removed 6 Twist the filter counterclockwise until it is disengaged Remove the filter and quickly hold it upright 7 Drain the filter before disposing of it in the trash The filter can be discarded along with the everyday trash 8 Remove and discard the protective cap from the new filter cartridge 9 Mark the current date on the label of the new filter ca...

Страница 18: ...nning If water flow does not stop immediately then replace the solenoid Low water flow Supply water pressure is less than required Water pressure must be between 40 and 105 psi Filter is plugged Replace filter Solenoid water valve not opening fully Replace solenoid water valve No water flow No electrical power Restore power to the unit Water shut off valve s closed Open all shut off valves one is ...

Страница 19: ... Board NFC filter board ON OFF switch Molex connector for extension cable RS232 comm Water valve 120VAC 120VAC 120VAC Electrical Box inside water dispenser Electrical Line IN 3 3 volts RS232 comm Extension cable for NFC board Can be 18 inches for local use OR 18 ft for remote use Built in Filtered Water Dispenser Wiring Diagram Ferrite Bead Mfr Fair Rite Part 0443167251 ...

Страница 20: ......

Отзывы: