Installation and Maintenance Manual

Troubleshooting

Problem

Possible Cause

Action To Take

No water dispense

The main water valve is closed

Open the valve

The power switch is set to OFF

Set the power switch to ON

Malfunction in the ribbon cable connection/ 

spade connectors

Repair connection to main circuit board

The water inlet solenoid is not working

Bypass the solenoid and replace it

The aluminium fusion block is frozen

Defrost the aluminium fusion block 

Reduce the thermostat setting

The low voltage transformer is not working

Replace the transformer

Problem

Possible Cause

Action To Take

Low flow dispense

The filter is clogged

Replace the filter

The main water valve is not fully opened

Open the valve

The flow control valve is not fully opened 

(sparkling water only)

Open the valve

The CO

2

 cylinder is empty (sparkling water 

only)

Replace the cylinder

Problem

Possible Cause

Action To Take

Sparkling water doesn’t 

come out

The CO

2

 cylinder is empty

Replace the cylinder

The pump is not working

Force the pump to start 

Replace the pump if broken

The solenoid is not working

Repair or replace the solenoid

The flow control valve is too tight

Open the valve

Problem

Possible Cause

Action To Take

Water is not cold enough

The thermostat is not adjusted properly

Adjust the thermostat

The condenser is dirty

Clean the condenser

The fan is not working

Replace the fan

Cold or not warm enough air is blowing 

through the condenser

Check for faulty compressor or gas leak on 

the refrigerant circuit and repair

Malfunction in the over temperature switch/

relay

Switch the machine off and wait 5 minute for 

restart 

Replace if broken

The compressor is not working

Replace the compressor

Leak in the refrigeration system

Refrigeration system requires repair or 

replacement

Problem

Possible Cause

Action To Take

Hot water is not hot

The power switch is off

Switch on the boiler

The safety therm-o-disk has tripped

Reset the therm-o-disk

Disconnected wires to the boiler

Connect the wires

Содержание DSBS130UVPC

Страница 1: ...u Begin Requirements for Installation 7 Mounting Dimensions 7 Operating Environment 8 Water 8 Electrical 8 Tools You Will Need 9 Unpacking the Kit 9 What s in the Kit 10 Installing the Machine 11 Operating the Keypad 16 Routine Maintenance 17 Troubleshooting 20 Replacement Parts 23 NOTICE Read the instructions in this manual and retain for future reference Installation and Maintenance Manual DSBS1...

Страница 2: ...ctive 2006 95 EC O O the protection requirements of the Electromagnetic Compatibility Directive 2004 108 EC The electrical safety of the product is ensured only when it is properly connected to an efficient legally compliant grounding circuit UL standard for safety of drinking water coolers ANSI UL 399 Issued 2008 08 22 Ed 7 Rev 2013 10 18 CSA standard for refrigeration equipment CSA C22 2 No 120 ...

Страница 3: ... should be taken to a dedicated recycling center for electrical and electronic equipment Immediately prior to scrapping cut off the power cable For more information on the treatment recovery and recycling of this product please contact the appropriate local office the waste disposal service or the reseller from which the product was purchased These products contain no CFCs or HFCs which contribute...

Страница 4: ...cold sparkling water room temperature still water and or hot water O O Natural materials throughout stainless steel aluminum O O Internal components made entirely of stainless steel O O DRY COOLING technology a noiseless low maintenance and innovative cooling system which allows for great performance and compact size O O Made entirely of stainless steel O O Anti bacterial UV lamp at dispensing poi...

Страница 5: ...rd Thermostat Cold sparkling dispenser Room temperature still dispenser Cold still dispenser DSBS130UVPC DSBSH130UVPC DSBS130UVPC keypad DSBSH130UVPC keypad Keypad Drip tray Boiler switch Power button Water inlet CO2 inlet Power cord Thermostat Cold sparkling dispenser Hot dispensers Cold still dispenser ...

Страница 6: ... pipe ø 1 4 ø 1 4 Power 110V 60Hz 110V 60Hz Power consumption 200W 2A 1130W 9 4A Working room temperature Min 41 F Max 107 6 F Min 5 C Max 42 C Min 41 F Max 107 6 F Min 5 C Max 42 C UNIT WEIGHT lb kg 67 5 30 6 67 5 30 6 SHIPPING WEIGHT lb kg 72 32 6 72 32 6 Dimensions W x D x H in mm 10 26 x 19 23 x 16 44 261 x 488 x 418 10 26 x 19 23 x 16 44 261 x 488 x 418 Dispensing area height in mm 10 99 279 ...

Страница 7: ...28 711mm Height 12 75 324mm Depth 3 88 99mm Diameter 8 203mm Width 3 25 83mm Footprint 10 3 wide x 19 2 deep 261mm x 488mm DSBS130UVPC DSBSH130UVPC Over counter includes 4 clearance on sides and back Under counter Water filter CO2 cylinder typical 20 pound Width 18 3 465mm Depth 23 2 589mm Height 20 5 520 7mm Footprint 10 3 wide x 19 2 deep 261mm x 488mm ...

Страница 8: ...r cooler to a water main that supplies drinking water only O O Use of 1 4 diameter connections is recommended O O Turn off the main water inlet tap if the unit is not to be used for a long period Electrical O O Check that the voltage shown on the serial number plate corresponds to the voltage being supplied at the installation site O O Do not use extension cables or multiple power sockets The mach...

Страница 9: ...nts to ensure that they are not damaged Contact the carrier immediately if there has been any damage during shipping NOTICE Ensure that your machine is installed by a qualified technician in compliance with the manufacturer s instructions and the local safety guidelines NOTICE Only qualified technicians should access the internal components of your machine 2 8 adjustable wrenches 1 10 adjustable p...

Страница 10: ... 1 DSBS130UVPC or DSBSH130UVPC water cooler 1 CO2 regulator 1 external water filter 2 3 8 quick connect connector 1 supply hose 1 2 ips x 3 8 tube x 12 long 1 water shutoff valve 1 water pressure regulator 1 10 coil CO2 tubing natural 1 4 OD 1 3 8 x 3 8 quick connect connector 1 10 coil water tubing blue 1 4 OD 1 10 coil water tubing blue 3 8 OD PLUS ...

Страница 11: ...t to under counter wall 2 Use 4 Phillips head screws to mount filter head to bracket 3 Remove cap from filter Insert filter into filter head and turn clockwise right until it stops When installing external water filler within the DSCABBSH cabinet please refer to the following mounting instructions 1 Use 3 Phillips head screws and washers to mount filter bracket to cabinet mounting strip as shown b...

Страница 12: ...hine Water source threaded fitting Water source open 3 8 pipe Water filter 3 8 quick connect adapter 1 4 x 1 4 Water shutoff valve Water pressure regulator Water piping cut to size 1 4 Water tubing cut to size To water cooler Short 3 8 3 8 pipe Using the quick connect fittings To connect 1 Make clean 90 cut to piping end 2 Push piping straight into fitting until it stops 3 Pull back to check that ...

Страница 13: ...to place 4 Connect external water and CO2 piping 5 Plug the machine into the wall socket and turn it on 1 Connect the power cable to the nearest socket 2 Flip the power switch at the rear of the machine A to the I position A B Water input Water input CO2 input CO2 input DSBS130UVPC DSBS130UVPC DSBSH130UVPC DSBSH130UVPC A B A B A B ...

Страница 14: ...ever turn on the boiler unless you have filled the machine with water NOTICE Never turn on the boiler when the inlet water is disconnected 1 Flip the boiler switch at the rear of the machine to the I position 2 After around 10 minutes the water reaches the setted temperature CAUTION Hot water reaches 185 F Keep children away Hot boiling water and steam will scald if spilled on skin Do not touch th...

Страница 15: ...ads 50 to 58 psi max 9 Re purge the line for sparkling water NOTICE The water will flow flat at first then gradually become more sparkling as the line is purged of still water 10 Allow machine to complete initial chilldown NOTICE Complete water heating will require around 10 minutes The machine should not be used as a water dispenser until heating is complete ...

Страница 16: ... To stop dispensing your water serving Release the button for that dispenser Operating the Keypad DSBSH130UVPC To dispense your water serving Hold down the button for that dispenser Note For safety reason to dispense hot water you must press and hold down the 2 hot water buttons at the same time To stop dispensing your water serving Release the button for that dispenser ...

Страница 17: ... to clean the product Metal fibers have a tendency to disintegrate and release small metal particles that are embedded in the surface Metal particles oxidize and give the impression that the surface of the product is rusting Do not use abrasive cleaners or abrasive pads as these will scratch the surface of the product Do not use a water jet O O To remove limescale use a slightly acidic product e g...

Страница 18: ...ze the machine NOTICE This operation must be carried out by your ELKAY reseller or by a qualified technician When required O O Replace the UV lamp CAUTION The light emitted by the ultra violet lamp may cause serious burns to the eyes and skin Disconnect the electrical source of supply of the UV radiation before opening the machine 1 Disconnect the unit from its electrical source 2 Once the unit is...

Страница 19: ...19 1000003719 Rev A 02 2017 O O Set the thermostat 1 Set the thermostat between 5 and 6 to control the temperature of the cold water COLDER OFF 1 2 3 4 5 6 7 ...

Страница 20: ...e Cause Action To Take Sparkling water doesn t come out The CO2 cylinder is empty Replace the cylinder The pump is not working Force the pump to start Replace the pump if broken The solenoid is not working Repair or replace the solenoid The flow control valve is too tight Open the valve Problem Possible Cause Action To Take Water is not cold enough The thermostat is not adjusted properly Adjust th...

Страница 21: ...2 tank Replace seal The CO2 exit pressure lower than 36 psi 2 5 bar Set the pressure between 55 60 psi 3 5 4 bar A reset is needed Turn the machine off and back on Problem Possible Cause Action To Take Only CO2 gas comes out when sparkling water button is pressed The pump runs for 4 minutes continuously Check why the water is not entering the unit and fix it The water valve is closed Open the valv...

Страница 22: ...22 DSBS130UVPC and DSBSH130UVPC Installation and Maintenance Manual Contacting Customer Support Elkay Manufacturing Company 2222 Camden Court Oak Brook IL 60523 800 726 0553 ...

Страница 23: ...000003895 Exit Solenoid Vavle hot x x 1000003896 Flow Control 6mm x x 1000003897 Flow CONTROL 8mm x x 1000003898 Transformer 110 24 x 1000002636 Lock with 2 Keys x x 1000002637 UV OUT Pipe x x 1000003901 UV OUT Inverter x x 1000003902 Blusoda DripTray and Grill complet Set x 1000003904 BOILER TERMODISK 87 x 1000003905 BOILER SAFETY TERMODISK 110 x 1000003906 BOILER EVO NO PRESSURE 1 Lt 1000W 110V ...

Страница 24: ...160217 ...

Отзывы: