DSBS130UVPC and DSBSH130UVPC
Installation and Maintenance Manual
Annually
O
O
Replace the water filter after 6000 gallons or a maximum of 1 year, or earlier depending on water quality.
NOTICE:
The filter head has an internal shutoff valve that stops the flow of water when the filter is
removed. It is not necessary to shut off the water supply.
1. Turn used filter counterclockwise (to the left) 1/4 turn to remove from filter head. Pull filter away from head
and remove.
2. Remove the cap from the new filter. Place the cap on the used filter to seal it.
3. Insert the new filter into the filter head and turn the filter clockwise (to the right) until it stops.
4. Place a receptacle under the still water dispenser and dispense continuously for a minimum of two gallons to
purge air and fine carbon particles from filter.
O
O
Sanitize the machine
NOTICE:
This operation must be carried out by your ELKAY reseller or by a qualified technician.
When required
O
O
Replace the UV lamp
CAUTION:
The light emitted by the ultra-violet lamp may cause serious burns to the eyes and skin.
Disconnect the electrical source of supply of the UV radiation before opening the machine.
1. Disconnect the unit from its electrical source.
2. Once the unit is shut down, rotate and remove the nozzle and remove
the top cover unscrewing the two screws on the sides of the nozzle
(A).
3. Disconnect the electrical connector of the UV OUT lamp. Pull the lamp
removing it from its fitting holder —handling it carefully.
4. Insert the new lamp and reconnect the connector — handling it carefully.
5. Repeat the procedure for all the dispensing valves.
6. The used UV lamps can be disposed at your local waste management site.
NOTICE:
This operation must be carried out by your ELKAY reseller or by a qualified technician.
NOTICE:
For the replacement of UV OUT pipe is not necessary to turn water off.
A
A