KOMET 200 - 600
10.8
Emergency mode
In case a safety device (LSA, LSI, SLA or SLZ) is faulty, emergency mode is
possible. After a warning time of 10 seconds, the gate can be moved in an
emergency mode by using BA or BZ (dead man’s function). During the
warning time as well as during the emergency mode the warning light is
flashing. Emergency mode by radio remote control BT or BTG) is not possible
due to safety reasons.
WARNING!
Even when a safety device is faulty, the gate can be moved by BA and
BZ. The buttons BA and BZ therefore have to be installed in such a way,
that the gate can be seen during movement.
WARNING!
Are external devices -giving a constant signal (e.g. timer) - connected to
BA or BZ, these devices can activate the emergency mode and move the
gate when a safety feature is faulty or active.
WARNING!
In case the multi-functional relay is used for an additional radio remote
channel, which is connected to BA or BZ, the emergency mode can be
started by radio remote control. In this case only fixed transmitters
should be used in such away, that the gate can be seen during
movement.
43