background image

 

Elektroschloss E 205

 

 

2

 

1 Preface 

1.1 General 

notes 

These operating instructions must be available on site at all times. It should be 
read thoroughly by all persons who use, or service the appliances. Improper 
usage or servicing or ignoring the operating instructions can be a source of 
danger for persons, or result in material damage. If the meaning of any part of 
these instructions isn’t clear, then please contact ELKA-Torantriebe GmbH u. 
Co. Betriebs KG before you use the appliance. 

This applies to all setup procedures, fault finding, disposal of material, care 
and servicing of the appliance. The accident prevention regulations and 
applicable technical regulations (e.g. safety or electrical) and environment 
protection regulations of the country in which the appliance is used also apply. 

All repairs on the appliances must be carried out by qualified persons. ELKA-
Torantriebe GmbH u. Co. Betriebs KG accepts no liability for damage which is 
caused by using the appliance for purposes other than those for which it is 
built. 

ELKA-Torantriebe GmbH u. Co. Betriebs KG cannot recognise every possible 
source of danger in advance. If the appliance is used other than in the 
recommended manner, the user must ascertain that no danger for himself or 
others will result from this use. He should also ascertain that the planned use 
will have no detrimental effect on the appliance itself. The appliance should 
only be used when all safety equipment is available and in working order. All 
faults which could be a source of danger to the user or to third persons must 
be eliminated immediately. All warning and safety notices on the appliances 
must be kept legible. 

All electrical periphery equipment which is connected to the appliance must 
have a CE Mark, which ensures that it conforms to the relevant EEC 
regulations. Neither mechanical nor electrical alterations to the appliance, 
without explicit agreement of the manufacturer, are allowed. All alterations or 
extensions to the appliance must be carried out with parts which ELKA-
Torantriebe GmbH u. Co. Betriebs KG have defined as suitable for such 
alterations, and be carried out by qualified personnel. Please note that with 
any alteration of the product, no matter whether mechanical or electrical, the 
warranty expires and the conformity is revoked. Only the use of ELKA 
accessories and original ELKA spare parts is allowed. In case of any 
contravention ELKA disclaims liability of any kind. 

  

 

INFORMATION! 

The operation of the system within CEN countries must also be conformant 
with the European safety-relevant directives and standards. 

  

We reserve the right to make technical improvements without prior notice.

 

  

Intelligent Security & Fire Ltd.

Содержание E 205

Страница 1: ...of original operating manual D ID V2_0 03 13 ELKA Torantriebe GmbH u Co Betriebs KG Phone 49 0 48 61 96 90 0 Dithmarscher Str 9 Fax 49 0 48 61 96 90 90 25832 T nning E mail info ELKA Torantriebe de Ge...

Страница 2: ...right 3 1 3 Information regarding installation instruction 3 2 Electromagnetic Bolt E 205 4 2 1 Usage 4 2 2 Technical data 4 2 3 Electrical connection 4 2 4 Installation measurements 8 2 5 Emergency r...

Страница 3: ...ll result from this use He should also ascertain that the planned use will have no detrimental effect on the appliance itself The appliance should only be used when all safety equipment is available a...

Страница 4: ...ed ATTENTION points to a potentially dangerous situation which can cause property damage if it is not avoided REMARK Important notice for installation or functioning 1 2 Copyright The operating manual...

Страница 5: ...rox 1 0A during stop position Degree of protection IP43 Emergency release With key cylinder lock Measurements W x H x L 94 x 295 x 58mm Stroke 50mm Table 1 2 3 Electrical connection The cross section...

Страница 6: ...connectable through the warning light connection and the main transformer of the controller MO 36 Connect the electromagnetic bolt E 205 to the transformer clamp of the main board secondary winding o...

Страница 7: ...wing 2 Connect the electromagnetic bolt E 205 to the transformer clamp of the main board secondary wiring of the toroid transformer The supply of the toroid transformer is switched over one conductor...

Страница 8: ...ce should be connected to the supply voltage 230Vac by a qualified electrician only Installation example controller MO 34 Drawing 3 With other controllers the power supply has to come through a separa...

Страница 9: ...schloss E 205 8 2 4 Installation measurements Installation for locking downwards The length of the pin is 50mm from the lower edge of the housing Drawing 4 I n t e l l i g e n t S e c u r i t y F i r...

Страница 10: ...ed position only Do not move the pin into an in between position Engage by turning the key counter clockwise The enclosed single cylinder lock can be replaced by another single cylinder lock or by a d...