Elektroschloss E 205

 

 

4

 

Electromagnetic Bolt E 205 

2.1 Usage 

Electromagnetic bolt E 205 to lock swing gates. The bolt locks either 
downwards or to the side. 

  

 

When using the electromagnetic bolt sidewards, it must be protected from 
moisture by a cover (on site). 

  

2.2 Technical 

data 

Power supply 

24Vac (Alternating current) 

Maximum current 

approx. 6.0A during stroke movement 
approx. 1.0A during stop position 

Degree of protection 

IP43 

Emergency release 

With key (cylinder lock) 

Measurements (W x H x L) 

94 x 295 x 58mm 

Stroke 50mm 

Table 1 

  

2.3 Electrical 

connection 

The cross section of the cable to the bolt depends on the distance between 
the controller and the electromagnetic bolt: 

up to 50m: 1.5mm

2

 

  

 

Please note that with an increasing distance between controller and swing 
gate the range of the radio remote control decreases, since the radio remote 
control receiver is plugged onto the controller. 

  

Intelligent Security & Fire Ltd.

Содержание E 205

Страница 1: ...of original operating manual D ID V2_0 03 13 ELKA Torantriebe GmbH u Co Betriebs KG Phone 49 0 48 61 96 90 0 Dithmarscher Str 9 Fax 49 0 48 61 96 90 90 25832 T nning E mail info ELKA Torantriebe de Ge...

Страница 2: ...right 3 1 3 Information regarding installation instruction 3 2 Electromagnetic Bolt E 205 4 2 1 Usage 4 2 2 Technical data 4 2 3 Electrical connection 4 2 4 Installation measurements 8 2 5 Emergency r...

Страница 3: ...ll result from this use He should also ascertain that the planned use will have no detrimental effect on the appliance itself The appliance should only be used when all safety equipment is available a...

Страница 4: ...ed ATTENTION points to a potentially dangerous situation which can cause property damage if it is not avoided REMARK Important notice for installation or functioning 1 2 Copyright The operating manual...

Страница 5: ...rox 1 0A during stop position Degree of protection IP43 Emergency release With key cylinder lock Measurements W x H x L 94 x 295 x 58mm Stroke 50mm Table 1 2 3 Electrical connection The cross section...

Страница 6: ...connectable through the warning light connection and the main transformer of the controller MO 36 Connect the electromagnetic bolt E 205 to the transformer clamp of the main board secondary winding o...

Страница 7: ...wing 2 Connect the electromagnetic bolt E 205 to the transformer clamp of the main board secondary wiring of the toroid transformer The supply of the toroid transformer is switched over one conductor...

Страница 8: ...ce should be connected to the supply voltage 230Vac by a qualified electrician only Installation example controller MO 34 Drawing 3 With other controllers the power supply has to come through a separa...

Страница 9: ...schloss E 205 8 2 4 Installation measurements Installation for locking downwards The length of the pin is 50mm from the lower edge of the housing Drawing 4 I n t e l l i g e n t S e c u r i t y F i r...

Страница 10: ...ed position only Do not move the pin into an in between position Engage by turning the key counter clockwise The enclosed single cylinder lock can be replaced by another single cylinder lock or by a d...

Отзывы: