ELIXAIR E 2100 Скачать руководство пользователя страница 7

 

 

 

The amount of dirt collected in the prefilters and collector cells determine how often they 

should be washed. Frequent discharges of electricity with a cracking sound is a clear 
indication that the collector cells should be washed. This means that so much dirt has 
accumulated on the collector plates that the distance between them is growing too small 
which is the cause for electrical discharges from one plate to another. 

 

1)  Opening the air purifier

 

 
- disconnect mains cable 

Note! Wait for ca. 1 minute to allow  the  high  voltage  in  the  collector  cells  to            

  discharge

 

- open the service door fully up so that it remains open resting on the support rod  
  (figure 2) 
- pull out the grid, the prefilters, the collector cells and the active carbon filters. 
 You must turn aside the prefilter spring to allow space to withdraw  the filters. 
 

2) Overall cleaning

 

 
Due to the large amount of dust and other particles that pass through the purifier, part of 

them adhere to inner and outer surfaces of the unit. You can clean the surfaces using either 
a vacuum cleaner or any ordinary mild detergent and a damp cloth. Remove the grid and the 
filters first to facilitate cleaning. Soak the grid in a mild detergent solution (

not cell detergent

and rinse it thoroughly with water. Let it dry in a horizontal or slanting position. 

 

3)  Washing the cell and the prefilter

 

 
Vacuum the prefilters before washing. Follow the washing instructions that apply to 

electronic collector cells. 

 

 

 

NOTE! 

Handle the electronic collector cell with care. The metal edges may be sharp. It is 

advisable to wear rubber gloves when washing the cell by soaking. Use original Elixair cell 
detergent only. Other types of detergents may damage the cell. We do not recommend 
washing the cell in a dish washing machine.

 

 

 
A) Spray wash

 

 
1. Spray the cells with warm water using e.g. a hand shower (figure 6) in a tub or sink. 
 
2. Spray solution of ELIXAIR cell detergent (4 parts water and 1 part detergent) on the 

collector plates of the cell. A flower spray bottle is handy for that purpose (figure 7). 

ELIXAIR 

cell detergent, 3 litres; product no. 600031, 10 litres; product no. 600050.

  

 

 

 

WARNING! 

Be careful not to splash or spray the detergent in your eyes and avoid repeated skin 
contact with it.

 

 
 

Содержание E 2100

Страница 1: ...ion of the electronic collector cell where they receive a powerful electrical charge 8 kV 4 The charged particles travel in the air stream to the collection section of the cell and are drawn to the co...

Страница 2: ...ed or where staying without any breathing protection is limited Warning Due to its mode of operation the electronic collector cell may occasionally emit sparks Never use the air purifier in a place wh...

Страница 3: ...he purifier It is even possible that the clean air from the exit would flow directly back to the intake of the purifier and leave the rest of the air in the room uncleaned For best cleaning results in...

Страница 4: ...move the two transport supports which hold the collector cells figure 2 6 Remove the plastic wrapping from the active carbon filters and install the filters in the grooves above the cells Close the do...

Страница 5: ...in the following sequence figure 5 Y C stop C speed I C speed II C speed III C stopY 3 Repeat the same test using the remote controller Point the infra red beam from the narrow end of the remote contr...

Страница 6: ...ying cigarette smoke efficiently In any large space where the content of dust and other impurities in the air is unusually high or where continuous use of the purifier on the highest fan speed is requ...

Страница 7: ...urfaces using either a vacuum cleaner or any ordinary mild detergent and a damp cloth Remove the grid and the filters first to facilitate cleaning Soak the grid in a mild detergent solution not cell d...

Страница 8: ...ght You can turn the cells over a few times to speed up drying 6 Check the ionization wires of the cell If the wires are dirty clean them carefully using a thin strip of plastic with a slit cut to it...

Страница 9: ...the cells entirely The proportions of the solution is 5 to 8 parts of water to one part of ELIXAIR cell detergent You can use the same solution 2 to 5 times 3 Immerse the cells and the prefilters if n...

Страница 10: ...nd then closing the door so that the spring loaded latches lock it tightly If the door is not properly closed the unit will not function because the safety switch controlling the door is not closed co...

Страница 11: ...with the applicable harmonized standards It complies with the essential elements of low voltage directive 73 23 ETY 93 68 ETY and the directive for compatibility on electricity EMC 89 336 ETY 93 68 ET...

Страница 12: ...SERVICE MEMO ELIXAIR E 2100 IR2 No Date of installation Act Act Act filter repl filte r filte r...

Отзывы: