ELIXAIR E 2100 Скачать руководство пользователя страница 10

 

 

 

 

4. Rinse the cells well with warm water and check that they are clean. If still dirty, you can 

wash them again.  It is not necessary that the plates get shining bright. Just check to see 
that there is no accumulation of dirt on them. 

 
5. 

 

Let the cells dry thoroughly in a well ventilated place, preferably overnight. You can 

turn the cells over a few times to speed up drying. Check that the ionization wires are clean. 

 

 

 

4) Reinstalling the cells and the filters

 

 
-  remove plastic wrappings from the active carbon filters before installing them 
 
-  make sure to install the cells the right way. The direction of air flow is from the grid 

towards the fan. Also check to see that the high voltage contact plates of the cells 
touch the counterpart contacts on the purifier frame. 

 
-  insert the prefilters in the grooves below the collector cells and return the spring in 

place to hold the aluminum frame of the filter. The purpose of the spring is both to 
prevent the vibration of the prefilter and to press the micro switch which controls the 
prefilter. 

 
-  push the grid in its groove and close the door by lifting up the latch and then closing 

the door so that the spring loaded latches lock it tightly. If the door is not properly 
closed, the unit will not function because the safety switch controlling the door is not 
closed. 

 
-  connecting the mains cable to the wall socket starts the air purifier at fan speed II (two 

green indicator lights of the control panel are on). The yellow indicator of high voltage 
is on continuously (figure 5,C) if the unit is running normally. 

 

Blinking indicator and/or cracking noise from the collector cell refers to high voltage short 
circuit. The short circuit may be caused by a wet collector cell, a distorted collector plate 
or a snapped ionization wire which is short circuited by other metal parts of the cell or the 
prefilter. Straighten the distorted plate or replace the wire. If necessary call your 
authorized  Elixair service.  

 
 

If the high voltage indicator light still indicates a fault (the light is off or it blinks) 
take the air purifier to authorized Elixair service. 

Using the purifier while the high 

voltage indicator is off or blinks may severely damage the unit.

 

 

 

-  mark on the memo sheet on page 34 the dates when you wash the purifier and 

change the active carbon filters. This facilitates the follow up of maintenance intervals 
and thus the proper and regular service of your air purifier. 

 

 

 
 

Содержание E 2100

Страница 1: ...ion of the electronic collector cell where they receive a powerful electrical charge 8 kV 4 The charged particles travel in the air stream to the collection section of the cell and are drawn to the co...

Страница 2: ...ed or where staying without any breathing protection is limited Warning Due to its mode of operation the electronic collector cell may occasionally emit sparks Never use the air purifier in a place wh...

Страница 3: ...he purifier It is even possible that the clean air from the exit would flow directly back to the intake of the purifier and leave the rest of the air in the room uncleaned For best cleaning results in...

Страница 4: ...move the two transport supports which hold the collector cells figure 2 6 Remove the plastic wrapping from the active carbon filters and install the filters in the grooves above the cells Close the do...

Страница 5: ...in the following sequence figure 5 Y C stop C speed I C speed II C speed III C stopY 3 Repeat the same test using the remote controller Point the infra red beam from the narrow end of the remote contr...

Страница 6: ...ying cigarette smoke efficiently In any large space where the content of dust and other impurities in the air is unusually high or where continuous use of the purifier on the highest fan speed is requ...

Страница 7: ...urfaces using either a vacuum cleaner or any ordinary mild detergent and a damp cloth Remove the grid and the filters first to facilitate cleaning Soak the grid in a mild detergent solution not cell d...

Страница 8: ...ght You can turn the cells over a few times to speed up drying 6 Check the ionization wires of the cell If the wires are dirty clean them carefully using a thin strip of plastic with a slit cut to it...

Страница 9: ...the cells entirely The proportions of the solution is 5 to 8 parts of water to one part of ELIXAIR cell detergent You can use the same solution 2 to 5 times 3 Immerse the cells and the prefilters if n...

Страница 10: ...nd then closing the door so that the spring loaded latches lock it tightly If the door is not properly closed the unit will not function because the safety switch controlling the door is not closed co...

Страница 11: ...with the applicable harmonized standards It complies with the essential elements of low voltage directive 73 23 ETY 93 68 ETY and the directive for compatibility on electricity EMC 89 336 ETY 93 68 ET...

Страница 12: ...SERVICE MEMO ELIXAIR E 2100 IR2 No Date of installation Act Act Act filter repl filte r filte r...

Отзывы: