OPTIONS (MENU 2)
General Options (Menu 2, 1)
The general options set options that relate to the general operation
of the EliteSuite keypad. The options shown in the screen shots
below are the default option configuration.
To modify options press the keys [1] or [2] to toggle the option on
or off. Pressing the [ENTER] key will save the options. Press the
[UP] or [DOWN] arrows to scroll through the available options.
Option 1 - Zone Type Option 1
If duplex zone (Option 2) is not enabled then Option 1
will set the zone input configuration (EOL or NO EOL).
EOL requires the use of 2 X 1K resistors to provide,
Short, Alarm, Closed and Tamper Monitoring. NO EOL
provides Alarm and Closed monitoring.
5
Enabled EOL resistors are used (2R Mode) (2 Zones).
6
Disabled NO EOL resistors are used (2 Zones).
Option 2 - Duplex Zone Operation
If Option 2 is set Option 1 does not have any function.
When option 2 is set the zones will use a 1K and 2K4
resistor and provide monitoring for 2 zones.
5
Enabled Duplex Zone Mode (4 Zones).
6
Disabled Option 1 sets the zone configuration.
Duplex Zone