Elite Suite ELT-KLCD Скачать руководство пользователя страница 1

 

ELT-KLCD EliteSuite Installation Manual 

 
 
 

Elite Suite 

 

 
 

 

 

 

 

ELT-KLCD 

EliteSuite LCD Keypad 

Installation Manual 

Содержание ELT-KLCD

Страница 1: ...ELT KLCD EliteSuite Installation Manual Elite Suite ELT KLCD EliteSuite LCD Keypad Installation Manual...

Страница 2: ...FORMATION First Publication Draft Document Release Only Updated fire zone information Second Publication Option Menu Navigation Updated Card Reader Interface Options Added Third Publication Slave Keyp...

Страница 3: ...10 Device Options Device Config Menu 2 10 Display Contrast Device Config Menu 3 11 Version Info Device Config Menu 4 12 Device Default Device Config Menu 5 12 LOCAL INSTALLER LOGIN 13 TIMING MENU 1 14...

Страница 4: ...EliteSuite condominium control keypad and installer programming functions Hardware Compatibility This manual is written for hardware verison 208 4010 030 or higher and covers firmware application 1 22...

Страница 5: ...be made in a daisy chain configuration avoiding star and stub connections Figure 1 Condominium Keypad Communication Keypad Wire Loom Colour Coding The condominium keypads are supplied with a wire loom...

Страница 6: ...e N and N terminals Figure 3 Wire Loom Colour Coding and Function When using more than one PSU to supply multiple wiring runs of condominium keypads only connect the 12 output of ONE power supply unit...

Страница 7: ...in the option settings Refer to the General Options Section on Page 16 for the programming of the zone configuration When using a tamper input on a device the tamper contacts must be normally closed...

Страница 8: ...Input Wiring Configuration on Page 3 Figure 7 Fire Smoke Detection Input When a fire zone is connected to a zone input that is used in the duplex zone configuration a fire zone fault will NOT BE show...

Страница 9: ...mode enabled 8 zones in total available This setup is shown in Error Reference source not found Standard wiring mode 6 zones in total available This setup is shown in Figure 9 The choice between the...

Страница 10: ...put can be programmed to either Follow the status of the alarm siren time or the fire alarm setting Follow the armed disarmed status of the keypad Connect a relay or other interface device to this ope...

Страница 11: ...ount Proximity Card Reader Each slave reader device communicates with the keypad via a PRX SAM Standalone Module Board This module also allows control of an electronic lock device with the onboard rel...

Страница 12: ...in Slave Mode see Device Options for configuration Each slave reader device communicates with the keypad via connection of their primary network lines to the secondary network lines of the master keyp...

Страница 13: ...on and device defaulting The device configuration menu can only be accessed when the device powers up It is not able to be accessed when the system is operational Address Selection Device Config Menu...

Страница 14: ...isabled Master mode is entered on start up Option 2 to 8 Reserved Display Contrast Device Config Menu 3 By default the contrast of the EliteSuite LCD Keypad is set to the optimal viewing and performan...

Страница 15: ...sented in the display screens shown above For the latest firmware release versions and change notifications please visit the Integrated Control Technology website at www integratedcontroltechnology co...

Страница 16: ...ered in this setting is now the local installer code This code is programmed system wide when an update is performed To disable the Installer Code on ALL EliteSuite keypads Recommended delete the code...

Страница 17: ...m 0 to 255 seconds Default 30 Seconds The cursor will flash on the digit you are currently modifying entering a number or pressing the RIGHT or LEFT arrows will move the cursor to another digit Progra...

Страница 18: ...ds entered will be automatically increased to 5 seconds to ensure correct reader operation Reader Left Open Timer Menu 1 5 The Reader Left Open Timer is programmable from 0 to 255 seconds Default 45 S...

Страница 19: ...ion 1 If duplex zone Option 2 is not enabled then Option 1 will set the zone input configuration EOL or NO EOL EOL requires the use of 2 X 1K resistors to provide Short Alarm Closed and Tamper Monitor...

Страница 20: ...bled the system will power up disarmed regardless of the system status at the time power was lost 6 Disabled the system will power up in an exit delay condition if the power to the EliteSuite device w...

Страница 21: ...larm status Option 7 PGM Output Follows Area Status 5 Enabled the PGM Output will be enabled when the EliteSuite system is armed and disabled when the system is disarmed 6 Disabled the PGM Output will...

Страница 22: ...ll save the options Press the UP or DOWN arrows to scroll through the available options Changes to the Display Option settings require the keypad to be restarted before the changes take effect Option...

Страница 23: ...Enabled the system can be FAST ARMED by pressing and holding the closed padlock key 6 Disabled FAST ARMING is disabled Option 2 Allow Fast Stay Arming 5 Enabled the system can be FAST STAY by pressing...

Страница 24: ...Force Arming 5 Enabled the system can be FAST FORCE armed by pressing and holding the FORCE key 6 Disabled FAST FORCE arming is disabled Option 5 6 7 and 8 Reserved 5 Reserved 6 Reserved Do not modif...

Страница 25: ...s Press the UP or DOWN arrows to scroll through the available options Option 1 Report Arming and Disarming 5 Enabled the EliteSuite keypad will send a message to the system controller when the system...

Страница 26: ...ystem will report any zone fault trouble condition to the system controller This will not indicate the zone that has the fault as this will be shown on the local keypad and in the trouble view menu 6...

Страница 27: ...report extending information such as the device tamper and fire loop trouble conditions These conditions do not generate an alarm in the system locally but can be used to generate an event at the loca...

Страница 28: ...ough the available options Option 1 1 3 Silent Panic 5 Enabled the system will send a silent panic alarm to the front desk when the 1 3 keys are held for a period of 2 seconds No message will be displ...

Страница 29: ...ys will not cause any alarm Option 4 User 8 Duress Code Enabled 5 Enabled the system will enable user code 8 to be a duress code user and on login will send a duress code to the central station or on...

Страница 30: ...0 the display will change the character displayed in the same way you enter text on a mobile phone To clear the text display press the FORCE key To move to the next configuration screen press the ENT...

Страница 31: ...ayed fire zone and will generate the fire delay beeping and require the user to follow the delay fire zone procedures to prevent a full fire alarm from being activated Zone Options The zone options se...

Страница 32: ...a stay zone Option 3 Force Zone 5 Enabled the zone can be force armed when it is not ready to be armed A force armed zone will automatically be included in the alarm processing when the zone restores...

Страница 33: ...es all feedback Please go to our website or use the information below Integrated Control Technology P O Box 302 340 Unit C North Harbour Post Centre 6 Ascension Place Auckland Mairangi Bay New Zealand...

Страница 34: ......

Страница 35: ......

Страница 36: ...Unit C 6 Ascension Place Mairangi Bay P O Box 302 340 North Harbour Auckland New Zealand Phone 64 9 476 7124 y Fax 64 9 476 7128 www integratedcontroltechnology com...