background image

37

S L - 3 0 0 0   P A R T S   L I S T

M A I N T E N A N C E

1. Make sure the reversing sensor is functioning properly (see page 18).

2. Make sure the gate track is clear of dirt, rocks or other substances.

3. Make sure the wheels are operating smoothly on the track.

4. If you hear alarm, refer to page 30.

5. Clean the cover on a regular basis.

6. For a list of parts, refer to page 36 and this page.

Please call your local service company.

Q402 1/2 HP  

 

Q403 1 HP

Electronic Box Assembly

Multiple Parts “Q” Numbers

#OmniControl Board Accessories

+Operator Serial No. and Model No. Required When Ordering

Q003 - Chain Bolt
Q004 - Chain Bracket
Q005 - SL-3000 Chassis
Q006 - PC Board Nuts (1 Set)
Q014 - Drive Sprocket
Q015 - Gear Reducer
Q016 - Limited Switch Drive Sprocket
Q018 - 1/2 HP Electric Motor
Q020 - Drive Belt
Q021 - Gear Pulley
Q025 - Motor Pulley
Q027 - Motor Capacitor
Q028 - Manual Crank
Q030 - Limit Switch / Chain
Q039 - Drive Belt, DM and 1 HP
Q237 - Crank Input
Q254 - Cover HD Polyethylene
Q329 - Limit Switch
Q400 - Omni Main PCB
Q401 - Omni 1 Horsepower Board

#

Q404 - Omni Alarm
Q407 - Omni Motor harness 1HP
Q408 - Electronic Power Strip
Q409 - Electronic Access Panel
Q410 - Surge Suppressor Terminal Block
Q420 - Omni Motor Harness
Q421 - Omni Motor Harness DM
A ELD - Loop Detector

#

O-OMNI EXB - Omni Option Board

#

O-QCC OMNI - QCC Access ID

#

O-DC-SL
O-DC-SL DM

Power Back-Up Unit

Q065 - Drive Belt (DM)
Q123 - Back-Up Motor DC 12V
Q143 - Chassis DC Back-Up
Q151 - Hardware Kit
Q164 - Drive Belt
Q177 - Wire Harness DC-1000
Q209 - Pulley DC-1000 1/2 ID

Idler Sprocket Assembly

Q013

Limit Switch Assembly

Q024

Q010 - Limited Switch Box Cover
Q023 - Limit Switch Box
Q031 - Limit Switch / Shaft
Q032 - Limit Switch Adjustment Nuts
Q033 - Limit Switch Sprocket
Q101 - Limit Switch Bearing Holder
Q156 - Collar 3/8 in

A H-110 - Chain no. 41 (10 ft)
A H-111 - Chain no. 40 (10 ft)
A H-112 - Chain no. 41 (Nickel Plated)
A H-113 - Master Link no. 41
A H-125 - Master Link no. 40

Do not touch

me unless you are 

an authorized 

service technician!

call toll free for 

technical support:

1-888-ELITE-10

Содержание SL-3000-UL Series

Страница 1: ...V 1102 Click on the desired topic in the Bookmarks column or Table of Contents to select page...

Страница 2: ...justing Gate Traveling Distance 17 Adjustable Timer 17 Two Way Adjustable Reversing Sensor 18 Master and Slave with Timer On 19 Master and Slave with Timer Off 20 Solenoid Maglock J3 Connection 21 Ins...

Страница 3: ...n a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment Swinging gates shall not open into public access ar...

Страница 4: ...bottom edge of a vehicular vertical lift gate 3 One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate 4 A hard wired contact sensor shall be located and i...

Страница 5: ...UST reverse on contact with a rigid object or stop when an object activates the non contact sensors After adjusting the force or the limit of travel retest the gate operator Failure to adjust and rete...

Страница 6: ...rage or parking area associated therewith Commercial General access vehicular gate operator Class II A vehicular gate opera tor or system intended for use in a commer cial location or building such as...

Страница 7: ...permit a 2 1 4 inch sphere to pass through any location including the area of the adjacent fence covered when the gate is in the open position Install the gate operator according to the manufacturer s...

Страница 8: ...height including the area of the adjacent fence covered when the gate is in the open position Always be certain that the gate area is clear of pedestrians before operating the gate R O L E O F E N D...

Страница 9: ...etween Gate and Wall or Other Object Gate in Fully Opened Position 1 4 Clearance from Top of Gate 5 8 G AT E P O S T W A R N I N G For safety reasons a physical stop must be installed on the gate prio...

Страница 10: ...cedure The UL required Warning Signs must be installed in plain view and on both sides of each gate installed Each sign is made with fas tening holes in each corner and should be permanently secured i...

Страница 11: ...ross the path of a moving gate Property owners must never allow anyone to hang or ride on the gate Property owners must never mount any gate operating device near the gate s path The SL 3000 Series is...

Страница 12: ...te Weight 2000 lbs Maximum Pull 180 lbs Recommended Gate Setup Configuration Warning Signs Attached on Both Sides of Gate Non Pinch Rollers Sensor Edges Sensor Edges Non Pinch Rollers Warning Sign Cle...

Страница 13: ...It is highly recommended installing over travel stops at both ends of the gate rail in any type of installation to prevent derailing R E A R I N S TA L L AT I O N S REASON CHAIN IS NOT VISIBLE F R O N...

Страница 14: ...the chain access slot on the one side of the cover to the exact specifications Important For safe operation of the gate opener do not cut the slots any wider or longer than shown DO NOT modify the hou...

Страница 15: ...on Physical Stops on Both Ends of Rail Cover over Wheel Physical Stops on Both Ends of Rail 10 8 12 12 Red Head Fastener 1 2 x 3 1 2 Conduit Area Without Battery Back Up Follow gate manufacturers spec...

Страница 16: ...OOP CENTER LOOP GATE LOCKED 60 POWER OVERLOAD OFF W4 OPEN LEFT DC BACKUP ALARM SENSOR OPEN RIGHT 3 SENSORS RESET MOTOR 1 3 1 3 COMMAND PROCESSED ON G B MS LINK A MADE IN USA RADIO MER 60 OFF 1 3 ON OP...

Страница 17: ...Installation 12 gauge wire Elite Access Systems is not responsible for improper installation or failure to comply with all necessary local building codes 8 ft The earth ground rod must be located wit...

Страница 18: ...MER NSOR 60 OFF OPEN LEFT OPEN RIGHT 3 1 3 ON Timer OFF Set Timer 1 to 60 seconds Timer can be set from 1 to 60 seconds Timer ON or for push open push close type operation Timer OFF Note When using ma...

Страница 19: ...N If the power supply to the gate operator is less than 99 volts adjust the alarm by turning the alarm adjustment counter clockwise enough to actuate the alarm when obstructed but not sensitive enough...

Страница 20: ...ED 60 POWER OVERLOAD OFF W4 OPEN LEFT DC BACKUP ALARM SENSOR OPEN RIGHT 3 SENSORS RESET MOTOR 1 3 1 3 COMMAND PROCESSED ON G B MS LINK A MADE IN USA TIMER TIMER NSOR 60 OFF OPEN LEFT OPEN RIGHT 3 1 3...

Страница 21: ...PEN LEFT OPEN RIGHT 3 1 3 ON TIMER TIMER NSOR 60 OFF OFF OPEN LEFT OPEN RIGHT 3 1 3 ON Master Omni Board Slave Omni Board 1 Connect G from the master surge suppressor to G of the slave surge suppresso...

Страница 22: ...A Connection of a Solenoid or Magnetic Lock can be made using the J3 plug and three wires supplied with the unit J3 2 8 10 9 7 1 3 Insert 2 supplied wires into J3 plug 3 and 7 Motor Harness 3 Normally...

Страница 23: ...Common Normally Closed Normally Open Maglock 1 2 3 4 5 6 7 8 9 Master Slave RS485 Burglar Alarm Output Burglar Alarm Input Ground B A 10 11 12 13 14 15 16 Solenoid Gnd Gnd Gnd Gnd Gnd B A N O N O N O...

Страница 24: ...mally Closed 9 Normally Open CENTER SAFETY EXIT CENTER SAFETY EXIT FIRE DEPT 1 3 STRIKE OPEN RADIO RECEIVER TIMER SYSTEM ON EXIT LOOP ALARM SENSOR REVERSE SENSOR OPEN STOP CLOSE SAFETY LOOP CENTER LOO...

Страница 25: ...e option is needed H O U S E A L A R M P R O X I M I T Y S W I T C H CENTER SAFETY EXIT CENTER SAFETY EXIT FIRE DEPT 1 3 STRIKE OPEN RADIO RECEIVER TIMER SYSTEM ON EXIT LOOP ALARM SENSOR REVERSE SENSO...

Страница 26: ...ush button is dry contact and there are no jumper wires between them IMPORTANT The Stop button must be Normally Closed 2 4 and 6 are common on Omni Option board for a 4 wire installation N O N O Com C...

Страница 27: ...dio Receiver External Exit Loop Detector Master Slave Operator External Safety Loop Detector Photo Cell Phone Entry Push Button Card Reader Fire or Any Key Switch 4 7 8 0 HELP 9 1 2 3 5 6 Red 24 Volt...

Страница 28: ...safety loops or the electric fields will interfere with each other Home Run The wire is continuously wound in the loop saw slot for the required number of turns One turn shown Refer to table above The...

Страница 29: ...Wire 3 Wires Shown amount varies Refer to table Min 1 Home Run The wire is continuously wound in the loop saw slot for the required number of turns One turn shown Refer to table above The wire must be...

Страница 30: ...ng loaded pin Turn the power OFF to the gate operator and unlock the fire box Pull firmly on the T Handle to release the chain Option 2 Model DC 1000U SL OPTION A In case of power failure the gate ope...

Страница 31: ...onal stop button Refer to the next page Refer to troubleshooting table W4 W4 OFF ON OFF ON Disconnect the wire harnesses from OmniControl board Unscrew 3 nuts to remove board The gate is too heavy 1 T...

Страница 32: ...OSE 1 2 3 4 5 6 Stop Button 3 N C 4 Com W4 31 S T O P B U T T O N A L A R M S H U T O F F This is an important command required to stop the audio alarm in case it has been triggered Otherwise the alar...

Страница 33: ...ent protection for your installation to prevent injury Recommended Edge Sensor Locations Edge Sensor Recommended Location Edge Sensor Recommended Location SL Top View of Gate Operation Recommended Ins...

Страница 34: ...nected to Sensor Input Gate in Open Position Fence Danger Edge Sensor Connected to Safety Input Non Pinch Rollers 4 Wires go to Gate Operator Omni Control Board and Electronic Box Terminals Sensing Ed...

Страница 35: ...Light Remains ON Always W4 OFF ON Reset Motor LED Light flashes once then System On LED slowly flashes Remote Control has malfunctioned in the ON Position Radio Receiver in the Gate Operator has malfu...

Страница 36: ...is is a normal response of the gate operator It does not represent necessarily that there is a problem TIMER LED BLINKING And COMMAND PROCESSED LED BLINKING 1 There is a command holding the gate open...

Страница 37: ...SL SL DM Q409 Q400 O OMNI EXB Q401 Q006 Q410 Q254 UL Q255 NON UL Q408 Q402 1 2 HP Q403 1 HP Q404 Q005 O QCC OMNI Q013 Q018 Q027 Q025 Q237 Q028 Q021 Q030 Q016 Q015 Q014 Electronic Box Assembly A ELD N...

Страница 38: ...elt DM and 1 HP Q237 Crank Input Q254 Cover HD Polyethylene Q329 Limit Switch Q400 Omni Main PCB Q401 Omni 1 Horsepower Board Q404 Omni Alarm Q407 Omni Motor harness 1HP Q408 Electronic Power Strip Q4...

Страница 39: ...T S External Safety Loop Detectors Card Reader Outdoor Digital Lock Outdoor Digital Lock with Intercom Indoor Intercom Speaker Outdoor Intercom Speaker Three Push Button Remote Control System Key Stat...

Отзывы: