background image

35

T R O U B L E S H O O T I N G   T A B L E

OVERLOAD LED ON

And 

POWER LED OFF

1.Short circuit at terminals 8 and 10
2.Short circuit at any of the loop detectors 

in the board

3.Short circuit in the control board

1.Remove the short circuit condition at 

the terminals

2.Remove the defective loop detector
3.Send the board to repair

OVERLOAD LED ON

And

POWER LED ON

1. Excessive current draw at terminal 10
2. Over-voltage at the 120 VAC line input

1. Reduce the accessories load from 

terminal 10

2. Verify your electrical power

SYSTEM ON LED FLASHING

1. One limit switch is faulty (Rapid Flashing)
2. Motor thermal fuse has popped-out

(Slowly Flashing)

1.Test the limit switches and wire 

connections, fix the fault

2.Reset the motor

REVERSE SENSOR LED ON

1.Gate has encountered and obstruction 

during traveling

2.Reverse sensor is extra sensitive

1.Remove the obstruction
2.Turn the reverse sensor switch counter 
clockwise a little more and try again

ALARM SENSOR LED ON

1.Gate encountered an obstruction during

traveling

2.Alarm sensor is extra sensitive

1.Remove the obstruction
2.Turn the alarm sensor switch counter 
clockwise a little more and try again

COMMAND PROCESSED

LED ON

1. There is a command hold active

1.This is a normal response of the gate 

operator. It does not represent necessarily 
that there is a problem.

TIMER LED BLINKING

And

COMMAND PROCESSED 

LED BLINKING

1. There is a command holding the gate 

open

1.This is a normal response of the gate operator. 

It does not represent necessarily that there is a 
problem. Check inputs for command.

TIMER LED BLINKING,

COMMAND PROCESSED

LED BLINKING

And

REVERSE SENSOR LED ON

1.Gate has reopened because it encountered 

an obstruction while closing.

1.Any re-new command will resume normal 

operation. Check for obstructions.

AUDIO ALARM ON

1.Gate has encountered two consecutive 

obstructions while trying to close or open

1.Any re-new command will resume normal 

operation but not a radio command. Check 
for obstructions.

2.You can stop the alarm by using the stop  button.

ANY 

"LOOP LED" ON

And 

NO VEHICLE ON THE

SENSING AREA

1.The loop detector needs to be reset.
2.The wire loop has been disrupted
3.The loop detector needs to work in a 

different frequency

4.The loop detector is too sensitive

1.Reset the loop detector (If you use Elite 

Plug-in Loop detectors, change the setting 
for sensitivity and come back to your original 
setting).

2.Verify and correct connections
3.Set a different working frequency
4.Decrease the sensitivity of the loop detector

CONDITION

POSSIBLE CAUSES

SOLUTION

In the United States, Canada and Puerto Rico,

call toll free for technical support:

1-888-ELITE-10

Содержание SL-3000-UL Series

Страница 1: ...V 1102 Click on the desired topic in the Bookmarks column or Table of Contents to select page...

Страница 2: ...justing Gate Traveling Distance 17 Adjustable Timer 17 Two Way Adjustable Reversing Sensor 18 Master and Slave with Timer On 19 Master and Slave with Timer Off 20 Solenoid Maglock J3 Connection 21 Ins...

Страница 3: ...n a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment Swinging gates shall not open into public access ar...

Страница 4: ...bottom edge of a vehicular vertical lift gate 3 One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate 4 A hard wired contact sensor shall be located and i...

Страница 5: ...UST reverse on contact with a rigid object or stop when an object activates the non contact sensors After adjusting the force or the limit of travel retest the gate operator Failure to adjust and rete...

Страница 6: ...rage or parking area associated therewith Commercial General access vehicular gate operator Class II A vehicular gate opera tor or system intended for use in a commer cial location or building such as...

Страница 7: ...permit a 2 1 4 inch sphere to pass through any location including the area of the adjacent fence covered when the gate is in the open position Install the gate operator according to the manufacturer s...

Страница 8: ...height including the area of the adjacent fence covered when the gate is in the open position Always be certain that the gate area is clear of pedestrians before operating the gate R O L E O F E N D...

Страница 9: ...etween Gate and Wall or Other Object Gate in Fully Opened Position 1 4 Clearance from Top of Gate 5 8 G AT E P O S T W A R N I N G For safety reasons a physical stop must be installed on the gate prio...

Страница 10: ...cedure The UL required Warning Signs must be installed in plain view and on both sides of each gate installed Each sign is made with fas tening holes in each corner and should be permanently secured i...

Страница 11: ...ross the path of a moving gate Property owners must never allow anyone to hang or ride on the gate Property owners must never mount any gate operating device near the gate s path The SL 3000 Series is...

Страница 12: ...te Weight 2000 lbs Maximum Pull 180 lbs Recommended Gate Setup Configuration Warning Signs Attached on Both Sides of Gate Non Pinch Rollers Sensor Edges Sensor Edges Non Pinch Rollers Warning Sign Cle...

Страница 13: ...It is highly recommended installing over travel stops at both ends of the gate rail in any type of installation to prevent derailing R E A R I N S TA L L AT I O N S REASON CHAIN IS NOT VISIBLE F R O N...

Страница 14: ...the chain access slot on the one side of the cover to the exact specifications Important For safe operation of the gate opener do not cut the slots any wider or longer than shown DO NOT modify the hou...

Страница 15: ...on Physical Stops on Both Ends of Rail Cover over Wheel Physical Stops on Both Ends of Rail 10 8 12 12 Red Head Fastener 1 2 x 3 1 2 Conduit Area Without Battery Back Up Follow gate manufacturers spec...

Страница 16: ...OOP CENTER LOOP GATE LOCKED 60 POWER OVERLOAD OFF W4 OPEN LEFT DC BACKUP ALARM SENSOR OPEN RIGHT 3 SENSORS RESET MOTOR 1 3 1 3 COMMAND PROCESSED ON G B MS LINK A MADE IN USA RADIO MER 60 OFF 1 3 ON OP...

Страница 17: ...Installation 12 gauge wire Elite Access Systems is not responsible for improper installation or failure to comply with all necessary local building codes 8 ft The earth ground rod must be located wit...

Страница 18: ...MER NSOR 60 OFF OPEN LEFT OPEN RIGHT 3 1 3 ON Timer OFF Set Timer 1 to 60 seconds Timer can be set from 1 to 60 seconds Timer ON or for push open push close type operation Timer OFF Note When using ma...

Страница 19: ...N If the power supply to the gate operator is less than 99 volts adjust the alarm by turning the alarm adjustment counter clockwise enough to actuate the alarm when obstructed but not sensitive enough...

Страница 20: ...ED 60 POWER OVERLOAD OFF W4 OPEN LEFT DC BACKUP ALARM SENSOR OPEN RIGHT 3 SENSORS RESET MOTOR 1 3 1 3 COMMAND PROCESSED ON G B MS LINK A MADE IN USA TIMER TIMER NSOR 60 OFF OPEN LEFT OPEN RIGHT 3 1 3...

Страница 21: ...PEN LEFT OPEN RIGHT 3 1 3 ON TIMER TIMER NSOR 60 OFF OFF OPEN LEFT OPEN RIGHT 3 1 3 ON Master Omni Board Slave Omni Board 1 Connect G from the master surge suppressor to G of the slave surge suppresso...

Страница 22: ...A Connection of a Solenoid or Magnetic Lock can be made using the J3 plug and three wires supplied with the unit J3 2 8 10 9 7 1 3 Insert 2 supplied wires into J3 plug 3 and 7 Motor Harness 3 Normally...

Страница 23: ...Common Normally Closed Normally Open Maglock 1 2 3 4 5 6 7 8 9 Master Slave RS485 Burglar Alarm Output Burglar Alarm Input Ground B A 10 11 12 13 14 15 16 Solenoid Gnd Gnd Gnd Gnd Gnd B A N O N O N O...

Страница 24: ...mally Closed 9 Normally Open CENTER SAFETY EXIT CENTER SAFETY EXIT FIRE DEPT 1 3 STRIKE OPEN RADIO RECEIVER TIMER SYSTEM ON EXIT LOOP ALARM SENSOR REVERSE SENSOR OPEN STOP CLOSE SAFETY LOOP CENTER LOO...

Страница 25: ...e option is needed H O U S E A L A R M P R O X I M I T Y S W I T C H CENTER SAFETY EXIT CENTER SAFETY EXIT FIRE DEPT 1 3 STRIKE OPEN RADIO RECEIVER TIMER SYSTEM ON EXIT LOOP ALARM SENSOR REVERSE SENSO...

Страница 26: ...ush button is dry contact and there are no jumper wires between them IMPORTANT The Stop button must be Normally Closed 2 4 and 6 are common on Omni Option board for a 4 wire installation N O N O Com C...

Страница 27: ...dio Receiver External Exit Loop Detector Master Slave Operator External Safety Loop Detector Photo Cell Phone Entry Push Button Card Reader Fire or Any Key Switch 4 7 8 0 HELP 9 1 2 3 5 6 Red 24 Volt...

Страница 28: ...safety loops or the electric fields will interfere with each other Home Run The wire is continuously wound in the loop saw slot for the required number of turns One turn shown Refer to table above The...

Страница 29: ...Wire 3 Wires Shown amount varies Refer to table Min 1 Home Run The wire is continuously wound in the loop saw slot for the required number of turns One turn shown Refer to table above The wire must be...

Страница 30: ...ng loaded pin Turn the power OFF to the gate operator and unlock the fire box Pull firmly on the T Handle to release the chain Option 2 Model DC 1000U SL OPTION A In case of power failure the gate ope...

Страница 31: ...onal stop button Refer to the next page Refer to troubleshooting table W4 W4 OFF ON OFF ON Disconnect the wire harnesses from OmniControl board Unscrew 3 nuts to remove board The gate is too heavy 1 T...

Страница 32: ...OSE 1 2 3 4 5 6 Stop Button 3 N C 4 Com W4 31 S T O P B U T T O N A L A R M S H U T O F F This is an important command required to stop the audio alarm in case it has been triggered Otherwise the alar...

Страница 33: ...ent protection for your installation to prevent injury Recommended Edge Sensor Locations Edge Sensor Recommended Location Edge Sensor Recommended Location SL Top View of Gate Operation Recommended Ins...

Страница 34: ...nected to Sensor Input Gate in Open Position Fence Danger Edge Sensor Connected to Safety Input Non Pinch Rollers 4 Wires go to Gate Operator Omni Control Board and Electronic Box Terminals Sensing Ed...

Страница 35: ...Light Remains ON Always W4 OFF ON Reset Motor LED Light flashes once then System On LED slowly flashes Remote Control has malfunctioned in the ON Position Radio Receiver in the Gate Operator has malfu...

Страница 36: ...is is a normal response of the gate operator It does not represent necessarily that there is a problem TIMER LED BLINKING And COMMAND PROCESSED LED BLINKING 1 There is a command holding the gate open...

Страница 37: ...SL SL DM Q409 Q400 O OMNI EXB Q401 Q006 Q410 Q254 UL Q255 NON UL Q408 Q402 1 2 HP Q403 1 HP Q404 Q005 O QCC OMNI Q013 Q018 Q027 Q025 Q237 Q028 Q021 Q030 Q016 Q015 Q014 Electronic Box Assembly A ELD N...

Страница 38: ...elt DM and 1 HP Q237 Crank Input Q254 Cover HD Polyethylene Q329 Limit Switch Q400 Omni Main PCB Q401 Omni 1 Horsepower Board Q404 Omni Alarm Q407 Omni Motor harness 1HP Q408 Electronic Power Strip Q4...

Страница 39: ...T S External Safety Loop Detectors Card Reader Outdoor Digital Lock Outdoor Digital Lock with Intercom Indoor Intercom Speaker Outdoor Intercom Speaker Three Push Button Remote Control System Key Stat...

Отзывы: