12
14. LAMPHEADS ON/OFF
15. FUSES FOR LAMPHEADS
13. LAMPHEADS
Important :
When plugging in a lamphead connector, first push in the front part, then firmly press in the
whole plug, the rear part being secured by the locking spring.
Different modelling lamps require corresponding fuses.
Slow blow fuses will not protect the modelling lamp.
The fast blow fuse will protect the triac of the modelling lamp
circuit, the lamp and therefore the flash tube.
Connect the lamphead. The ventilator fan functions even in OFF mode.
After a studio session, leaving the generator switched on, but the lampheads OFF extends lamp
and tube life
.
If the power display does not illuminate i.e. ON/OFF appears not to function, the lamphead is
incorrectly fitted, the connector is damaged or it is an old lamphead unadapted.
Modelling
switch
FUSE
W 110V 240V
200 2AF 2AF
300 5AF 2,5AF
650 10AF 5AF
ATTENTION
use only
recommanded fuse
1 5 0 0
+
-
Use only FAST BLOW FUSES, type 5 x 20 mm corresponding to the label
on each lamphead.
DO NOT PLUG IN OR UNPLUG LAMPCORDS WHILE THE DISPLAYS ARE ON i.e. ILLUMINATED.
2
2
2
2
2
1
1
1
1
1
Fuse
The indicator on the IRS will «blink» on the generator when its channel has not been selected.
However, selecting its channel «O» will re-activate the units response system.
The units function like and are therefore totally compatible with Micro AS power packs and 750 Micro.
USE OF IRS