![Elimko E-PR-110 Series Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/elimko/e-pr-110-series/e-pr-110-series_user-manual_2389131006.webp)
9
8
4.3 - Dimensions
Figure
E-PR-110 Dimensions
and Panel Mounting
4.1
144 mm
144mm
Elimko
137mm
137 mm
20 mm
10 mm
110 mm
4.4 - Panel Mounting
138 mm
Panel Cut Hole
Figure 4.2 E-PR-110 Panel Cut Hole
E-PR-110 device should be installed inside a suitable grounded metal
enclosure (panel). This must prevent the live parts being accessible to
human hands and metal tools.
.
E-PR-110 does not include a power switch. Therefore, the power supply
of the device and power outputs must be wired through the proper fuse or circuit
breaker.
To minimize the pick-up of electrical noise, the wiring of low voltage lines,
particularly the sensor input should be routed away from the high-current power
cables. Where it is not possible, use shielded cables which are grounded.
The cables used for powering the controller and the power outputs must conform
to the standards IEC 60245 and IEC 60227.
(See Section 7. CONNECTION DIAGRAMS)