53
English
• The machine is equipped with a device to lock it into position: the transport lock. This is
a switch mounted onto the instrument panel. If due to vibrations the wires to this switch
have come loose, an electric circuit will be opened; this has the same effect as engaging
the transport lock. The machine obviously blocks in its set position as a result. (If the
transport lock is engaged, all LEDs on the instrument panel are off.)
2. The machine is blocked in transport mode.
Just like in work mode, the electrical actuator must receive a signal before taking action. Analo-
gously, the problem will probably have to be found in the controls or in the actuator.
The examination will be identical to the earlier mentioned procedure.
• It is unlikely that the magnetic detection for activating the All-in-oneTM control lever is
the culprit, unless the magnetic switch is dislocated and a static metal object sits in the
detection area (read § 11.4.11).
• The issues regarding the limit switch are identical to the ones described earlier, albeit that
they apply to the actuator in extended position. Check the second LED (from the left) on
the instrument panel.
• The same examination applies for the relays.
• Since a defective actuator can also be the cause of the problem, the same test can be
performed as described above.
• The transport lock must also be inspected.