Electrical connection
The mains power supply must correspond to the rating
indicated on the plate situated inside the hood. If provided with
a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area. If it not fitted
with a plug (direct mains connection) or if the plug is not
located in an accessible area apply a double pole switch in
accordance with standards which assures the complete
disconnection of the mains under conditions relating to over-
current category III, in accordance with installation
instructions.
Warning!
Before re-connecting the hood circuit to the mains
supply and checking the efficient function, always check that
the mains cable is correctly assembled.
Mounting
Before beginning installation:
•
Check that the product purchased is of a suitable size for
the chosen installation area.
• To facilitate installation, remove the fat filters and the
other parts allowed and described here, dismantle and
mount it.
To remove see also the relative paragraphs.
•
Remove the active carbon (*) filter/s if supplied (see also
relative paragraph). This/these is/are to be mounted only
if you want lo use the hood in the filtering version.
• Check (for transport reasons) that there is no other
supplied material inside the hood (e.g. packets with
screws (*), guarantees (*), etc.), eventually removing
them and keeping them.
•
If possible, disconnect and move freestanding or slide-in
range from cabinet opening to provide easier access to
rear wall/ceiling. Otherwise put a thick, protective
covering over countertop, cooktop or range to protect
from damage and debris. Select a flat surface for
assembling the unit. Cover that surface with a protective
covering and place all canopy hood parts and hardware
in it.
•
In addition check whether near the installation area of the
hood (in the area accessible also with the hood mounted)
an electric socket is available and it is possible to
connect a fumes discharge device to the outside (only
suction version).
• Carry out all the masonry work necessary (e.g.
installation of an electric socket and/or a hole for the
passage of the discharge tube).
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must
verify suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take
the weight of the hood.
Do not tile, grout or silicone this
appliance to the wall. Surface mounting only.
Remove the grease filter/s and the carbon filter frame.
Fig. 5-6-7-8
1.
Adjust extension of the hood support structure, as the
final height of the hood depends on this, and remember
that with installation completed the hood must be at least
50 cm above the cook-top for electric cookers and 75 cm
for gas or mixed cookers.
2.
Fix the two sections of the structure using 8 screws.
3.
Place the ceiling hole diagram directly above the cook-
top (the center of the diagram must match the center of
the cook-top and the edges must be parallel to the sides
of the cook-top – the side of the diagram with the wording
FRONT corresponds to the control panel side). Prepare
the electrical connection.
4.
Drill as shown (6 holes for 6 wall plugs – 4 plugs for
fixture), screw the outer screws leaving a space of about
1 cm. between the screw head and the ceiling.
5.
Fit an exhaust pipe inside the truss and connect it to the
motor compartment connection ring (exhaust pipe and
fixing brackets are not supplied).
6.
Hook the frame onto the 4 screws (see step 4).
CAUTION! The side of the truss with connection box
corresponds to the side of the control panel with hood
assembled.
7.
Tighten the 4 screws.
8.
Insert and tighten another 2 screws in the remaining free
holes for secure fixing.
9.
Carry out the electrical connection to the mains power
supply, only turn on the power supply upon completion of
assembly.
10.
For extractor versions (10A), connect the other end of the
exhaust pipe to the flue.
For filter versions (10F), fit deflector F to the truss and
secure it to the bracket supplied using 4 screws, then
connect the exhaust pipe to the connection ring located
on the deflector.
11.
Remove the fixing tabs placed on the lower part of the
chimney flue, set aside the tabs and screws.
12.
Apply the tabs to the inside of the upper section of the
chimney flue using one screw for each tab.
13.
Fix the upper sections of the telescopic chimney flue
(13a) to the pylon (13b).
The upper sections are recognizable by the air exit
perforations for use in the filter version.
14.
Block the sections with 2 screws (14a) to be inserted on
the tabs already mounted on one section of the chimney
flue (14b – see also the mounting sequence 11 -12).
15.
Remove the grease filter and slide in the lower section of
the cooker hood (during this operation slightly widen the
two sections to ease the insertion).
The front side of the cooker hood is recognizable by the
slit opening provided for the control panel.
Attention!
During this operation ensure to extract the
control panel plate and the electrical connection cables
for the lamps through the slit opening.
16.
Fix the lower section of the cooker hood to the pylon from
the bottom using 6 screws (16a), and on the sides using
4 screws (16b).
17.
Introduce the cables
CONNECTED
to the lamps and
connect the control panel to the plate.
ATTENTION!
THE PLATE CABLE CONNECTOR IS PROVIDED