12
Clock programming
The clock can be reprogrammed at any time except dur-
ing an active timed fuction.
The clock can be displayed in a twelve hour format and
velid clock times are from 1:00 to 12:59.
The clock can be reprogrammed pressing the “Timer”
button for 3 seconds, and after, the clock can be adjust-
ed with the “+” and “-” buttons.
The user can have minute increments / decrements of 1
minute, but if the user keep pressing the “+” / “-” buttons
for more than 1 second, the increments 7 decrements
will be of 5 minutes.
During this option the control will round to the nearest 5
minutes.
The user can finish on reprogramming the clock pressing
the “Timer” button.
After 1 minute of no button pressed the control will ac-
cept the programmed clock time and will add one minute
to the se clock.
Grease filter saturation alarm (Optional)
After thirty fan functional hours, the display will show
“Grease Filter” if the fan is active.
When this icon is shown in the display, the grease filters
installed are required to be washed.
To reset the grease filter saturation alarm the user must
press the “+” button for 5 seconds, after this action the
icon “Grease Filter” is not displayed, and the hood has
normal display operation.
Charcoal filter saturation alarm (Optional)
After one hundred and twenty fuctional hours of the fan,
the display will show “Charcoal Filter” if the fan is active.
When this icon flashes on display, the charcoal filters
installed are required to be replaced or reactivated.
To reset the charcoal filter saturation indication the user
must press the “-” button for 5 seconds, after this time
the icon “Charcoal Filter” is not displayed and the hood
has the normal display operation.
Audible signal activation and deactivation
The audible signals can be activated or deactivated
pressing the “Light” button for 5 seconds.
If the audible signal is activated, a tone must sound and
the “Snd” symbol must appear on the display for 3
seconds.
If the audible signal is deactivated, the “Snd” symbol must
appear on the display for 3 seconds and no tone must
sound.
Charcoal filter inclusion and exclusion
(Recirculating accessories)
The charcoal filter inclusion or exclusion can be set by
pressing the “+” and “-” buttons at the same time for 5
seconds.
The inclusion or exclusion of chacoal filter must be
selected while the lamps and the motor are OFF.
When the carcoal filter has been excluded, the charcoal
filter alarm is disabled.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Heat sensor
The control is equipped with a heat sensor that will turn
on the blower at third speed if excessive heat occurs
(over 149°F or 65°C) surrounding the control area.
If the blower is OFF or if it is operating at first speed, the
blower will be set automatically to third speed, the dis-
play shows the word “CArE” to indicate that heat sensor
has detected an excessive heat.
During this state, the user may raise the blower speed to
fourth speed but can not decrease the speed.
When the temperature level on the hood droops to nor-
mal, the blower will operate in the setting defined by the
user before the alarm occured.
Maintenance and User Service
Instructions
ATTENTION! Before performing any maintenance opera-
tion, isolate the hood from the electrical supply by switching
off at the connector and removing the connector fuse.
Or if the appliance has been connected through a plug and
socket, then the plug must be removed from the socket.
Cleaning
Do not spray cleaners directly to the control while cleaning
the Hood. The cooker hood should be cleaned regurarly
(at least with the same frequency with which you carry out
maintenance of the fat filters) internally and externally. Clean
using the cloth dampened with neutral liquid detergent. Do
not use abrasive products. DO NOT USE ALCOHOL!
WARNING:
Failure to carry out the basic cleaning recommendations of
the cooker hood and replacement of the filters may cause
fire risks.
The refore, we recommend oserving these instructions.
The manufacturer declines all responsibility for any dam-
age to the motor or any fire damage linked to inappropriate
maintenance or failure to observe the above safety recom-
mendations.
Grease Filter
Traps cooking grease particles.
This must be cleaned once a month using non aggressive
detergents, either by hand or in dishwasher, which must be
set to a low temperature and a short cycle. When washed
in a dishwasher, the grease filter may discolour slightly, but
this does not affect its filtering capacity.
To remove the grease filter, pull the spring release handle.
•
•
•
•
Содержание Hood