9
Electrical Connection
I
WARNING
ELECTRICAL SHOCK HAZARD.
DISCONNECT POWER BEFORE SERVICING. REPLACE ALL
PARTS AND PANELS BEFORE OPERATING. FAILURE TO DO
SO CAN RESULT IN DEATH OR ELECTRICAL SHOCK.
1
Remove the knockout and the Junction box cover, and
then install the conduit connector (cULus listed) in the
junction box.
A
B
A. Knockout
B. Junction box cover
2
Run 3 wires - black, white, and green - according to the
National Electrical Code and local codes and ordinances,
in 1⁄2” conduit from the service panel to the junction box.
A
B
C
D
E
F
A. White wires
B. Black wires
C. CUL listed wire connector
D. Yellow-green (or bare)
ground wire
E. Homepower supply cable
F. UL listed or CSA approved 1⁄2”
strain relief
i
WARNING
ELECTRICALLY GROUND THE BLOWER. CONNECT THE
GROUND WIRE TO THE GREEN AND YELLOW GROUND
WIRES IN THE TERMINAL BOX. FAILURE TO DO SO CAN
RESULT IN DEATH OR ELECTRICAL SHOCK.
3
Connect the black wire from the service panel to the black
or the red in the junction box. Connect the white to white
and green to green-yellow.
4
Close and secure the junction box cover.
Complete Installation
Replace filters.
Check operation of the hood.
If range hood does not operate:
• Check that the circuit breaker is not tripped or the house
fuse blown.
• Disconnect power supply. Check that wiring is correct.
To get the most efficient use from your new range hood,
read the “Mainteinance” section.
Keep your Installation Instructions and Use and Care Guide
close to range hood for easy reference.