Design and Functions
Each state has a meaning regarding whether an error occurred and how serious the error is.
The following table shows what states can be signalized by the five LEDs:
Table 1: Meaning of LED signals
LED
Colour Status
1
Meaning
PWR A
yellow
ON
Supply voltage channel A available
OFF
Supply voltage channel A not available
PWR B
yellow
ON
Supply voltage channel B available
OFF
Supply voltage channel B not available. The sensor head is in the energy saving
mode because of low voltage supply or there is no power supply at all.
RUN
green Flashing
5 Hz
Safe position data is transmitted via the interface
Flashing
1
2
/
3
Hz
The sensor head is operating in single-channel mode. Non-safe position infor-
mation is transmitted via the interface.
Static
light on
The sensor has been blocked intentionally. Also see: LED
ERR
.
ERR
red
OFF
No error
Flashing
1 Hz
At least one error has been detected, but it is not classified as a severe error.
Find more information on the problem in the Error Register (
The exact cause is transmitted via the interface to the evaluation unit as long as
the sensor is in dual-channel operation (
9.5.4) In single-channel operation;
no detailed error diagnosis is possible.
Further information on error clearance:
Flashing
irregular
frequency
The sensor had has blocked itself due to a severe error. The unit should be
replaced. The exact cause is communicated via a flashing code of the LED
ERR
(
TAPE
yellow
ON
Magnetic tape cannot be detected or is damaged
OFF
Magnetic tape is detected
Flashing
irregular
frequency
The sensor had has blocked itself due to a severe error. The unit should be
replaced. The exact cause is communicated via a flashing code of the LED
ERR
(
1
The status in bold define the faultless normal operation