![Elgo LIMAX44 RED Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/elgo/limax44-red/limax44-red_operating-manual_2388608032.webp)
- 32 -
Installation and First Start-Up
11.
IMPORTANT: Installation check!
The tape tension and the offset of the sensor are recommended values based on experience. What is es-
sential, however, is that the tape does not constantly rub on the sensor with the magnetic side during op-
eration. Occasional contact due to movement of the tape is not critical. Therefore, run an inspection
travel along the complete lifting height and control the distance between the tape and the guiding rail. If
the steel side is slightly pressed against the plastic guide the whole time, the mounting is ideal. Also check
the bottom side of the sensor at some points. If the sensor is slightly tilted, it is possible that the tape
slides perfectly into the guiding at the upper end but still touches the sensor with the magnetic side at the
lower end.
Fig. 15: Assessment of the vertical alignment of the sensor
Tape touches
the guide with
the steel side
Recommended
Wrong vertical
alignment
Enforced contact
between steel band and
polymer guide