![Elgo LIMAX44 RED Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/elgo/limax44-red/limax44-red_operating-manual_2388608030.webp)
- 30 -
Installation and First Start-Up
Fig. 12: Distance and orientation of the magnetic tape in relation to the sensor.
8.
Now adjust the distance between the tape and the sensor. For lifting heights up to 50 m we recommend
a distance of minimum 33
mm. This offset will ensure that the tape is correctly guided along the steel
side during operation. The distance can be increased later if it turns out that the tape still rubs against
the sensor with the magnetic side. In higher lifts, the distance can already be increased up to 5 cm at
the initial mounting. Make sure that the sensor is installed vertically. Misalignment will lead to an in-
creased wear.
9.
Now pass the tape through the sensor. Loosen the screws (Fig. 20 on page 38) to fix the polymer
guides and remove them. Then remount them with the tape in between.
10.
Check for correct mounting. Any irregularities and angular offsets have to be corrected!
Fig. 13: Assessment of the guiding rail of the tape in the sensor – twisted magnetic tape
8,
21
min. 33 mm
7.
8.
magnetic tape
mounting bracket
cabin
sensor
guidance
Tape is
skewed in
the guide
Tape is flat
in the guide