Operation modes and Commissioning
- 49 -
In case a floor which is already stored in the floor table is detected a second time during teach mode (within a
tolerance of ±
“Door minimum distance”
), the new detected position overwrites the position already available in
the table. In case this happens at a double-sided floor (double side information already stored in the table), only
the position detected on first side overwrites the position in the table. When the second side is detected, this
information is ignored (first side takes the leadership by definition).
Figure 18: Automatic learning of double sided floors
Table 8: Floor table as stored in CP in case of double sided floors learned automatically
Floor No.
Position
First side
Second side
#1
1000
X
#2
3000
X
#3
4000
X
#4
7000
X
X
#5
10000
X
NOTE!
When carrying out the learn trip by car call, it may happen that the highest floor is not detected:
Because of tolerances it may happen the car stops a very small distance below the highest floor.
In this case it would help to drive the cabin a small distance upwards by recall control.
The same applies for the lowest floor.
Front floors
(first side)
Rear floors
(second side)
Floor
sensor
first side
#5
7000mm
#4
7001mm
#5
10000mm
CP
Floor
sensor
second
side
#1(1st side)
1000mm
#3 (first side)
4000mm
#2 (2nd side)
3000mm
Содержание LIMAX33 CP-00 SERIES