Design and Functions
- 17 -
9.3
Parameter Level
9.3.1
Enter Paramater Level
Press
F
+
Incr/Abs
for 3 seconds at the same time:
P 01
appears in the display („0“ is flashing)
the parameter level is active
The corresponding key functions for programming are described in the previous section
9.3.2
Parameter Description
All available parameters are described in detail here:
P00 = Reserved for test purposes
P01 = The counting direction can be reversed here (setting 0 or 1).
P02 = No function / reserved
P03 = Selection of the decimal place
P04
= Actual value memory can be activated/deactivated here.
P05
= Keypad lock/ keypad enable (the parameter level always remains active)
P06 = Select the edge evaluation (x 1, x 2 x or x 4)
P07 = Measuring system selection:
The connected measuring system must be selected here:
Setting 0 = Inkrementelle Messsystemsignale A/B/Z (z. B. EMIX/LMIX/PMIX/FMIX oder Drehgeber)
Setting 1 = Incremental encoder signals A/A’, B/B’, Z/Z’ (for differential encoder types)
Setting 2 = Absolute signals of ELGO - EMAX (via RS422 interface)
Setting 3 = Absolute signals of ELGO - FMAX (via RS422 interface)
P08 = Multiplication factor:
For details of the pulse scaling refer to section
P09 = Reference value:
A reference value can be entered here which is taken over into the display when keys
F
+
►
are pressed
or the external reference input is activated.
P10
= Tool-offset:
An offset dimension can be defined here. By pressing the
►
or activating the external tool-offset input
the display will add this value to the actual value.
P11 = Saw blade thickness (Incr-Mode only):
In order to compensate the thickness of a saw blade of a saw machine, the value can be stored here.
P12
= Preset limit for relay 1 (min) activates when underrun
P13 = Preset limit for relay 2 (max) activates when overrun
P14 = Display brightness:
To adjust the brightness of the LED display digitally from 0 (darkest) to 9 (brightest).
P15 = No function / reserved
P16 = Default parameters:
Details about resetting the Z58 to the default parameters can be found in section
P17 = Measurement unit mm or inch:
Defines whether the position display is to be operated in millimeters or inches.
P20 = Analog (minimum value):
Enter the value at which the analog output controls 0 V resp. 0 / 4 mA.
P21 = Analog (maximum value):
Enter the value at which the analog output controls 10 V resp. 20 mA.
P22 … P98 are without function or reserved
P99 = Indicates the software version of the device (useful for service calls).