28
14. Only for Service
Service Register 90
How to access the service register? At first the security code in
R98
must be used
and the service enable must be activated
R90
.
With entering the service register R90, the following functions are selectable:
R 90 = 000001
Æ
Load customer adjustment
(Register
R88/2
adjustment)
R 90 = 000002
Æ
Clear
memory
15. Type designation
P
= position controller
Series
Program memory
1 = without
2 = with
Number of axes
Version
000 = Standard
001 = 1. Special version
Power supply
024 = 24 VDC
115 = 115 VAC
230 = 230 VAC
Encoder Inputs
0 = A/B
Æ
24VDC – 20 KHz PNP (active high)
1 = A/B/Z
Æ
24VDC – 20 KHz PNP (active high)
2 = A/B
Æ
5V-TTL - line receiver
3 = A/B/Z
Æ
5V-TTL - line re index pulse
8 = A/B
Æ
24VDC - NPN logic (active low)
Accessories
P = Analog output for X- axis
*
PP = Analog output for X- and Y- axes
*
EN =
NPN
inputs (active low)
S
=
Serial RS232 interface*
* In preparation
P 88 22 - 000 - 230 - XY - XXXXXX