9
Direction of Count
Press for three seconds gives access to the count direction
to toggle between
U
p and
D
own.
Decimal Places
Press for three seconds gives access to the number of decimal places.
to toggle between 1,2 or 3 decimal places.
Inch / Metric Switching
Press for three seconds gives access to either counting in inches or millimetres.
(
Inch
or
nn
).
Press to toggle between these settings
On completion of editing of any section, Press
F
to store value to RAM and return to "Config".
Press all four buttons again for three seconds to return indicator to operating mode.
General Technical Information
Indicators
Maximum counting frequency
- 10 kHz standard.
- 50 kHz option (specify at order stage)
- Series 56, 50 kHz standard.
Operating temperature
- 0 to 50 deg.C
Memory against supply failure
- 3 years
Current Consumption of Indicator
- LCD : 100mA operating
exluding Encoder
: 1mA standby
- LED
: 40mA
EE inputs
- PNP only.
These provide external contact control of datum and zero reset.
(Must be specified at order stage)
Encoders
Encoder specification
- 24 volt PNP or push pull.