background image

 

15

 

Liability exclusion / Guarantee 
 

We have checked the contents of this instruction manual carefully, to the best of our knowledge and 
belief for conformity with the described hardware and software. Nevertheless errors, mistakes or 
deviations can not be excluded, therefore we do not guarantee complete conformity. Necessary 
corrections will be included in the subsequent editions. We appreciate your ideas and improvement 
suggestions very much. Reprint, duplication and translation, even in extracts, are only allowed with a 
written authorization by the company ELGO Electric GmbH. We constantly strive for improving our 
products, therefore we keep all rights reserved for any technical modifications without any notice.  
 
ELGO Electric does not assume any liability for possible errors or mistakes. 
 
The guarantee period is one calendar year from the date of delivery and includes the delivered unit 
with all components. ELGO Electric GmbH will at its option replace or repair without charge defects at 
the unit or the included parts, verifiable caused by faulty manufacturing and/or material in spite of 
proper handling and compliance to the instruction manual.  
 
Damages verifiably not caused by ELGO Electric GmbH and due to improper handling are excluded 
from any guarantee e.g. by applying faulty voltage, diffusion of liquid into the interior of the engine, 
using force, scratching

 

Содержание 54 AG Series

Страница 1: ...Z54 Z56 Series Z54 56 000 E_41 99 doc Doku Art Nr 799000101 Programmable Position Indicators Series 54 For use with Encoders Series 56 For use with MX magnetic scale...

Страница 2: ...dit datum Offset 6 Edit Datum 1 bit 6 Edit Flexible Multiplier 6 Changing Display Value 7 Counter Configuration 7 Configuration Register 8 Direction of Count 9 Decimal Places 9 Inch Metric Switching 9...

Страница 3: ...xternal inputs The Range available is as follows Series 54 single axis indicator available in LED or LCD display formats Suitable for encoder feedback Series 56 single axis indicator available in LED...

Страница 4: ...s with a fixed offset that can be readily toggled Incremental Absolute operation When pressed on its own switches between absolute and incremental operation In many applications dimensions are given o...

Страница 5: ...fset It is only possible for the operator to edit the Datum and Datum Offset if the editing feature is unlocked in the configuration register XXX0X NB The Datum and Offset values incorporate any decim...

Страница 6: ...e is not possible when this feature is selected Press both buttons for three seconds any value may now be set in the normal way subtracts one bit press adds one bit press to the displayed value Edit F...

Страница 7: ...ment the digit between 0 and 9 stores the value to the internal RAM and returns the indicator to operating mode Counter Configuration F Press buttons for three seconds the Configuration mode is entere...

Страница 8: ...X X X X X Series 54 Encoder feedback only Series 56 Scale feedback only Display extinguish 0 No auto extinguish and no clamp extinguish 1 Total power off on with F button 2 Total power off after 5 min...

Страница 9: ...ction Press F to store value to RAM and return to Config Press all four buttons again for three seconds to return indicator to operating mode General Technical Information Indicators Maximum counting...

Страница 10: ...20 60 Maximum speed of travel 5m sec Cable length 3m standard up to 25m available Operating temperature 5 to 45 deg C Sealing IP66 Magnetic Tape MB20 50 xx x Resolution 0 1mm Operating temperature 5 t...

Страница 11: ...tion ST3 AC input Pin 1 L Pin 2 N Pin 3 E ST2 Encoder Pin 1 0 volts Pin 2 24 volts dc Pin 3 Channel A Pin 4 Channel B Pin 5 Screen ST3 Series 56 AG BU1 ST3 AC input Pin 1 L Pin 2 N Pin 3 E BU1 MX magn...

Страница 12: ...ns Outline Dimensions Side View 92mm 66mm 72 mm 96mm 62mm 68mm mm 107mm 76 95mm 90mm M6 60mm 30mm Panel Mounting Series 54 and 56 AG Enclosure Mounting Series 54 and 56 NG20 0 Power Supply 80mm 45mm D...

Страница 13: ...For 56 series indicators to operate on 110 230 v ac use the 024 version and order a separate NG20 0 power supply AG versions always include NG20 0 mounted inside the enclosure 600 For Version 230 or 1...

Страница 14: ...24 V DC 115 115VAC in 54 only 230 230VAC in 54 only Construction 000 standard 001 1 st special version etc Special Features EE External input AG Free standing Housing RS232 Serial port in 54 only M h...

Страница 15: ...ly strive for improving our products therefore we keep all rights reserved for any technical modifications without any notice ELGO Electric does not assume any liability for possible errors or mistake...