Elgar CW-M Series 

 

 

21 

3.7 Sense Connections  

The CW Series unit can be used with or without remote sense leads connected to the 
load. Where the sense leads (line and neutral sense) are connected determines the 
point at which the CW output voltage will be precisely regulated. 

As shipped, the units are configured for local sense operation. This is achieved by 
connecting shorting jumpers between the sense and AC output terminals of the rear 
panel output terminal block, as shown in Figure 3–8.   

When using remote sensing, the shorting jumpers must be removed, and the remote 
sense leads connected from the CW sense terminals to the load. The point of voltage 
regulation will now be at the load, and any voltage drop across the interconnecting 
output cable will be compensated. 

In the event that the external remote sense circuit opens, the CW maintains control of 
the output voltage by utilizing a redundant sense circuit. This redundant circuit is 
comprised of 10k

 resistors internally connected from the AC output terminals to the 

voltage control circuitry. However, since the unit is calibrated with the sense leads 
connected, this mode of operation will incur reduced accuracy in the AC output voltage 
because of the presence of the 10k

 resistors. 

 

Figure 3–8  Output Voltage Sensing Configuration 

 

Содержание CW 1251M

Страница 1: ...els CW 801M CW 1251M CW 2501M 2002 by Elgar Electronics Corporation This document contains information proprietary to Elgar Electronics Corporation The information contained herein is not to be duplic...

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ...presentatives shall in no circumstance be liable for any direct indirect special penal or consequential loss or damage of any nature resulting from the malfunction of the product Remedies under this w...

Страница 6: ...ii This page intentionally left blank...

Страница 7: ...must ensure that the output power lines are labeled properly as to the safety hazards and that any inadvertent contact with hazardous voltages is eliminated Guard against risks of electrical shock du...

Страница 8: ...sk of Electrical Shock CAUTION Refer to Accompanying Documents Off Supply Standby Supply On Supply Direct Current DC Alternating Three Phase Fuse Earth Ground Terminal Protective Conductor Terminal Cu...

Страница 9: ...s 8 3 INSTALLATION 9 3 1 Unpacking 9 3 2 Wire Gauge Selection 10 3 3 Mounting Instructions 13 3 4 Cooling 13 3 5 Power In Connections 18 3 6 Power Out Connections 20 3 7 Sense Connections 21 3 8 Paral...

Страница 10: ...15 Figure 3 4 Mounting Dimensions Top and Side Views CW 801M CW 1251M 16 Figure 3 5 Mounting Dimensions Top and Side Views CW 2501M 17 Figure 3 6 Input Power Connections 18 Figure 3 7 Output Power Con...

Страница 11: ...l parallel cable A two speed fan results in quieter operation at lower power levels Key features of the CW Series AC power sources include High performance value design Output available at front or re...

Страница 12: ...Elgar CW M Series This page intentionally left blank 2...

Страница 13: ...0 5 100 Hz above 100 Hz AC Noise Level 50m VRMS typical for CW 801M and CW 1251M 100m VRMS typical for CW 2501M Amplitude Stability 0 1 of full scale over 8 hours at constant line load and temperatur...

Страница 14: ...MS CW 1251M 0 to 18 6 ARMS CW 2501M Accuracy 2 of range for linear loads with current 0 2A for CW 801M and CW 1251M 0 4A for CW 2501M Resolution of Display 0 1A Frequency Range 45 to 500 Hz Accuracy 0...

Страница 15: ...nt large green LED display Protection and Isolation Overvoltage Set screw adjustable Overcurrent 10 turn potentiometer Accuracy 2 of range for linear loads with current 0 2 A for CW801M and CW1251M 0...

Страница 16: ...witches see Section 4 on page 25 Master or Slave field configuration Output disable enable at power up Overcurrent shutdown enable disable 2 6 Input Voltage and Frequency CW 801M 90 to 264 VAC 47 to 6...

Страница 17: ...W 1251M 61 lbs 28 kg CW 2501M 94 lbs 43 kg Regulatory Compliance CE mark LVD EN61010 1 1993 Amendment 2 EMC EN55011 1991 Group 1 Class A EN50082 1 1992 Environmental Cooling Dual fan speed with side a...

Страница 18: ...Elgar CW M Series 2 8 Options and Accessories L Locking knobs front panel potentiometers Rack Slide Kit Elgar part number K161570 01 Parallel Cable Elgar part number 890 497 40 8...

Страница 19: ...arrier agent Perform a visual inspection of the instrument when it is removed from the shipping container Check for shipping damage such as dents scratches distortion and damaged connectors If damage...

Страница 20: ...on properties are recommended for power source applications Avoid using published commercial utility wiring codes which are designed for the internal wiring of homes and buildings Although these codes...

Страница 21: ...ngth Where Column 3 value Entry of the table above Cable length One way cable length in feet Vloss Maximum loss in volts permitted within cable Special case Should the Vloss requirement be very loose...

Страница 22: ...d effects of The rated output voltage Transient voltages induced onto the conductors from any source The differential voltage to other nearby conductors and Safety margins to accommodate degradations...

Страница 23: ...contains the appropriate slides and mounting brackets If you elect not to use slides mount the unit with standard support angles to sustain the weight of the unit in the rack Note that the front pane...

Страница 24: ...Elgar CW M Series Figure 3 2 Mounting Dimensions Front and Rear Views CW 801M CW 1251M 14...

Страница 25: ...Elgar CW M Series Figure 3 3 Mounting Dimensions Front and Rear Views CW 2501M 15...

Страница 26: ...Elgar CW M Series Figure 3 4 Mounting Dimensions Top and Side Views CW 801M CW 1251M 16...

Страница 27: ...Elgar CW M Series Figure 3 5 Mounting Dimensions Top and Side Views CW 2501M 17...

Страница 28: ...er from the terminal block 2 Route the cables through the strain relief device Refer to Table 3 2 for cable recommendations 3 Connect SAFETY GROUND to the GROUND stud located next to the INPUT termina...

Страница 29: ...not available connect LINE and NEUT across any of the phases 4 Reinstall the protective cover on the terminal block Tighten the strain relief device CW Model North American International CW 801M 18A...

Страница 30: ...E to GROUND See Figure 3 7 below Most loads require NEUTRAL to be grounded The factory jumper may be removed if the load has a GROUND or if LINE or NEUTRAL voltages are held to less than 500 VRMS with...

Страница 31: ...removed and the remote sense leads connected from the CW sense terminals to the load The point of voltage regulation will now be at the load and any voltage drop across the interconnecting output cab...

Страница 32: ...inal block Twisted shielded leads for power and sense leads are recommended for the lowest noise operation If used shields should be connected to a CW output terminal block GND ground connector as sho...

Страница 33: ...Master Unit To Slave Units INPUT LINE INPUT LINE INPUT GND INPUT GND INPUT NEUT INPUT NEUT OUTPUT LINE OUTPUT LINE OUTPUT NEUT OUTPUT NEUT Connect the master unit s sense leads either locally or to t...

Страница 34: ...Elgar CW M Series This page intentionally left blank 24...

Страница 35: ...4 1 CW Rear Panel 4 1 CONFIG Dipswitch The CONFIG dipswitch comes preset from the factory for stand alone operation With these settings the unit powers up to the current voltage and operates in const...

Страница 36: ...urrent mode 8 OFF Current Shut off fault mode 9 12 Phase angle selections see Table 4 2 on page 31 Table 4 1 CONFIG Dipswitch Functions 4 2 Setting the CONFIG Dipswitch You may change the CONFIG dipsw...

Страница 37: ...allel and Multiphase Configurations To operate parallel and or multiphase configurations set the switches cables and wiring as shown in the examples below 4 3 1 Setup for Three Phase Two Paralleled pe...

Страница 38: ...Elgar CW M Series 4 3 2 Setup for Six in Parallel Configuration 28...

Страница 39: ...Elgar CW M Series 4 3 3 Setup for Six Phase Configuration 29...

Страница 40: ...Elgar CW M Series 4 3 4 Setup for Two Phase Configuration 30...

Страница 41: ...table below Lagging Phase Angle Switch 9 Switch 10 Switch 11 Switch 12 A 0 ON ON ON ON 330 ON OFF ON ON 315 OFF ON ON ON 300 OFF OFF ON ON 270 ON ON ON OFF C 240 ON OFF ON OFF 225 OFF ON ON OFF 210 O...

Страница 42: ...Elgar CW M Series This page intentionally left blank 32...

Страница 43: ...USTER These five controls and indicators located on the left side of the front panel are used to select and display the power supply s output voltage V RANGE HIGH LOW Switch This switch allows you to...

Страница 44: ...n slowly turn the adjustment counter clockwise until a fault is generated turning the output off p CURRENT FREQUENCY CLUSTER These six controls and indicators located in the center of the front panel...

Страница 45: ...ill restore normal operation 5 1 Parallel and Multiphase Operation Follow the instructions in Section 3 8 Section 3 9 and Section 4 to set up paralleled or multiphase units Turn on the slaves prior to...

Страница 46: ...on s front panel control setting The combined effect is full scale limited The impedance of the external analog control inputs is 10k ohms nominal Connect the voltage control signal to pin 1 Connect t...

Страница 47: ...circuit boards 6 2 Fuse Replacement Replacement fuses for the CW Series supply are listed below in Table 6 1 Ref Designator Location Rating Manufacturer Mfr P N Elgar P N F1 F2 Motherboard 25A 250V T...