20
USER MANUAL TPS/M 62000595 REV 03_
–
01/06/2021
2.2.
PROTECTION DEVICE
2.2.1.
GENERAL DIAGRAM
Mandatory
Safety protection (Magneto-thermal and differential) are mandatory according to
the nominal TPS characteristic.
An additional adequate protection
must be add
when electrical components
(cable, Equipment under test
–
EUT) cannot support TPS performance.
2.2.2.
RCD PROTECTION
A residual-current device (RCD), or residual-current circuit breaker (RCCB), is a device that
instantly breaks an electric circuit to prevent serious harm from an ongoing electric shock.
It's recommended to
use B type
RCD with a earth leakage current of
30 mA
according to the
nominal input characteristic (see section 1.2). The machine can absorb more than 100mA at high
frequency, be secure the RCD has the filter for high frequency.